2. 

When connection, please confirm SFP module RX and Tx port, the side of 
fiber optic corresponding insert Rx and Tx port, Make sure Tx and Rx port 
connection correctly, the another side of fiber connect to another device;  

3. 

after powered

please check the corresponding indicator light status. If 

light is on, show the link already connect normally, light is off, show the link 
is blocked. Please check circuit, confirm the opposite end device already 
start using. 

 Attention

  

Do not over bend the fiber, the radius of curvature should not be less than    
           10cm;  

Make sure the cleanliness of the fiber surface;   
Please do not look directly at the fiber optical connector, otherwise can  
           cause  eye damage.  

 

 

3.3 Inspection Before powered 

Please check if power socket supply power is correspond the specification or not;   
Please check if power supply, POE switch, rack already grounded correctly or not; 
Please check if PoE switch normally connect with other network equipment or not; 

3.4 Device initialization

 

 

After powered after turn on power, POE switch will automatically initialization. 
Indicator light will appear the following of situation;  

After powered, the power indicator light always keep ON, the other indicator light 
OFF.  

After around two second, except power indicator light, the other indicator light ON 
around two second, then OFF;  

Each port indicator light indicates the connection status of each port, it show 
POE switch start work normally.

  

 

 

 

 

Содержание S-16GE-2UG-LD-AI-VLAN

Страница 1: ...User Manual S 16GE 2UG LD AI VLAN 16 port Gigabit AI POE Switch...

Страница 2: ...hardware installment method and attention items The third section hardware connection Guide POE switch connection with other device and attention items The forth section technical specification Delar...

Страница 3: ...suitable for remote monitoring and power supply In the AI power supply mode the switch automatically detects the working status of the PD device and finds that the device abnormal automatically restar...

Страница 4: ...abnormal LINK ACT 17 18 Device connection LED Green blink Corresponding already connect normally Off Corresponding port don t connect normally RJ45 Port S 16GE 2UG LD AI VLAN support 16 port 10 100 10...

Страница 5: ...round connection in case lighting stroke In order to avoid the product sustain lighting stroke and extend using lifetime The second section Product Install 1 1 Install attention items Attention Avoid...

Страница 6: ...ture speed up insulation material aging processing seriously affect device use lifetime The POE switch working temperature and storage temperature humidity is as follow Environment Description Tempera...

Страница 7: ...gh to cause fatal damage to electronic equipment In order to reach better lightning protection effect please not the following Make sure the rack is in good touch with the ground Make sure the power s...

Страница 8: ...on the appropriate location of the rack crutch by bracket using the L shaped bracket to fix the two sides of rack with screw make sure POE switch is installed on the rack smooth and steady 5 Attention...

Страница 9: ...le length can not more than 100meter The Ethernet RJ45 port Auto MDI MDIX function default open when adopt Cat 5 cable to connect Ethernet network both standard Ethernet cable and crossover Ethernet c...

Страница 10: ...k directly at the fiber optical connector otherwise can cause eye damage 3 3 Inspection Before powered Please check if power socket supply power is correspond the specification or not Please check if...

Страница 11: ...orts 2 Gigabit SFP ports PoE 16 10 100Mbps RJ45 PoE ports Total power budget 150W Single port max 30W Indicator 18 Link Act indicator light 16 POE indicator light 1 Power indicator light Performance f...

Отзывы: