Securefast APX-15 Скачать руководство пользователя страница 2

2

3

NUL NUL GND  DECT NO

COM NC  REMO

DC  /  AC

Keypad Connection terminals

Com N/O

Exit Button

Electric Release

12v AC or DC

Fail Locked

0v / -

12v / +

Transformer

or

Power Supply

F
U
S
E

Note: Do not switch power on

until all connections are made

The APX-15 Keypad is a robust vandal resistant keypad which is suitable for Internal/External installations for
controlling an Electric Lock or Magnetic Lock. It can also be used to trigger an Automatic Door or Barrier.
The keypad can be connected to a 12v AC Transformer or 12v DC Regulated Power supply with a minimum
load rating of 1 amp. The maximum current draw of the Lock or Magnet is 2 amps. A Single User code or up to
50 codes can be added (2-8 digits long). The Relay of the keypad can be set for 1-99 seconds delay or can
be set to Toggle On/Off. Programming is done via the buttons using a 4 digit Master code.

NUL NUL GND  DECT NO

COM NC  REMO

DC  /  AC

Keypad Connection terminals

Com N/O

Exit Button

-

+

Regulated

Power Supply

12v DC 1A

F
U
S
E

Installation

Step 1.

Using the keypad backplate as a template fix to a flat/level surface.

(the keypad should be fitted at 1 to 1.5 metres from the floor).

Step 2.

Run 2 core 0.5mm2 cables through the wall for the Electric lock,

Power unit and Exit Button (if required). Seal cable entry hole.

Step 3.

Fit Transformer or Power supply as per Manufacturer instructions.

Fit Electric lock/Magnetic lock as per Manufacturer instructions.

If required fit Exit Button as per Manufacturer Instructions.

Step 4.

Connect the Electric lock and Exit Button (if required), then connect

the Transformer/Power supply as per the wiring detail below.

Fix the Keypad to the backplate with the Torx screw at the bottom.

Step 5.

Apply power to the Transformer/Power supply and check that the

Blue LED is lit on the keypad. If an Exit button is fitted press it and
check if the Yellow LED lights and the Electric Lock/Magnetic lock is
released.

Wiring detail for 12v AC or DC Electric Strike Fail Locked

Wiring detail for 12v DC Electric Strike Fail Un-Locked

Electric Release

12v DC

Fail Un-Locked

Note: Do not switch power on

until all connections are made

NUL NUL GND  DECT NO

COM NC  REMO

DC  /  AC

Keypad Connection terminals

Com N/O

Exit Button

F
U
S
E

Wiring detail for 12v DC Electro-Magnetic lock c/w Emergency Call Point

Magnetic Lock 12v DC

Note: Do not switch power on

until all connections are made

Regulated

Power Supply

12v DC 1A

-

+

-

+

Com

N/C

Emergency

Call Point

Please contact Technical for all other wiring configurations

Отзывы: