General information 

The SC-GSM M2 is an alarm system communicator with 2 types of operation. 
 

In standalone mode, 

it generates an SMS message and an alarm call from Contact ID reports from 

alarm control panels or from status changes in its own contact inputs. Operation: it compares the 
event codes of the reports from the alarm system (Contact ID) with the event codes predefined in 
the program table that require an alarm notification and, when the corresponding event code occurs, 
it sends the text assigned to the code as an SMS message to the specified phone numbers or triggers 
an alarm call (generating a siren sound). As a result, users can be notified of any alarm event with 
individual messages, i.e. not only the fact of the alarm, but also its location can be specified in the 
SMS message, and the user's activity - e.g. opening/closing - can be tracked by name. 
 

In transparent mode, 

the device is capable of GSM voice calls with phone line simulation. The device 

can connect the alarm system to the user via a mobile call or can be used as a simple phone line in 
other applications in places where a public phone line is not available (lifts, SOS or INFO call points, 
holiday homes, etc.) The device does not handle incoming calls and cannot ring the connected phone 
line device. 

 

 

1.1

 

Key features 

 

2 separate operating modes in one device 

 

Telephone line simulation for alarm TIP/RING communicator 

 

Send SMS and alarm calls based on up to 64 Contact ID codes  

 

Notification to 4 user phone numbers 

 

2 contact inputs, with independent signaling 

 

SMS forwarding to the specified phone number 

 

Setup and diagnostics via USB connection 
 
 

1.2

 

Difference compared to the SC-GSM previous model 

 

 

Instead of 32 events, 64 Contact ID events can be notified 

 

The timing settings for the notification can be freely parameterized 

 

Extended event log, every detail of the communication can be monitored 

 

No USB back-up memory 

 

No possibility to ring out on incoming calls 

 

The device programming software has changed  

Содержание SC-GSM M2

Страница 1: ...SC GSM M2 manual v2 0 1 EN S SC C G GS SM M M M2 2 Alarm system communicators that generate individual SMS messages and alarm calls via GSM network from Contact ID reports Installation manual v2 0...

Страница 2: ...Structure 4 3 Suggested wiring diagram 5 4 Required setting of alarm panel 5 5 Status signals 5 6 Settings 6 6 1 Standalone mode 7 6 2 Transparent mode 7 6 3 Contact inputs events setting 8 6 4 Gener...

Страница 3: ...ode the device is capable of GSM voice calls with phone line simulation The device can connect the alarm system to the user via a mobile call or can be used as a simple phone line in other application...

Страница 4: ...TN line for connection to TIP RING alarm panel input terminals Power supply terminals Power requirements DC 9 30V 300mA Alarm contact inputs Triggered to negative supply with dry contact SIM card hold...

Страница 5: ...will accept the Contact ID reports from alarm panel as a monitoring receiver and forward them to IP monitoring receiver Only after the reporting was acknowledged by monitoring station the acknowledge...

Страница 6: ...evice to the PC and select the appropriate serial port then push the Connect button For example Once connected device settings can be found on the following interface Attention To validate the changes...

Страница 7: ...filter does not take into account the Zone and Partition values To trigger an SMS message and alert CALL for a given event you need to select the phone numbers to be notified and enter the text of th...

Страница 8: ...dividually 6 4 General settings In this window you can change the parameters related to the operation of the communicator SIM PIN the PIN code of the inserted SIM card must be entered if PIN code requ...

Страница 9: ...ndow The administration window of SecurecomConfigurator contains the following basic information about the device The function of the administration icons is as follows Type of connection and operator...

Страница 10: ...GSM 2G GSM850MHz EGSM900MHz DCS1800MHz PCS1900MHz Supply voltage 9 V 30 V DC Rated current 100 mA Maximum current 300 mA Operating temperature 20 C 70 C Dimensions 40x80x15 mm 8 Device package content...

Отзывы: