Страница 1: ...Smart Programmable Thermostat H3747 Installation and commissioning guide...

Страница 2: ...ve product design and speci cations mentioned are liable to change System functionality information illustrations and product aesthetics published in the document may vary from those of your product 2...

Страница 3: ...rammable Thermostat Display PTD Pre paired Optional To be purchased separately WiFi Extender HC2 4 Add on WiFi adapter Temperature Sensor THS Additional temperature sensor for extra zones Extra PTD Ad...

Страница 4: ...lers Heat hotwater zones Communicates wirelessly with PTD temperature sensor and mobile app 7 year no quibble warranty No need for WiFi when programming schedule WiFi Extender HC2 4 Guaranteed 12 year...

Страница 5: ...What is covered Receiver H3747 1 Install Setup system using PTD 2 Programmable Thermostat Display PTD User mobile app 3 Test Establish communication How to 5...

Страница 6: ...47 Smart Programmer is compatible with most heating control systems and is ideal for compatible system boilers using spring return valves It can also work with combination boilers as well as heat pump...

Страница 7: ...ding the receiver for remote control Smartphone Version 11 0 and above Marshmallow version 6 0 and above Flat head screw driver Philips head screw driver Drill machine 2 5 mm drill bit Wire stripper P...

Страница 8: ...d hot water All graphics are for illustration purpose only Boiler Auto by pass Valve CT Hot water Two port zone valve Zone 1 Zone 2 PTD PTD TS Or Channel 1 Channel 2 Channel 3 Wireless connection Wire...

Страница 9: ...ing and hot water All graphics are for illustration purpose only Boiler BLE Auto by pass Valve CT Hot water Two port zone valve Zone 2 Zone 3 PTD TS Or Channel 2 Channel 4 Channel 3 Zone 1 PTD Channel...

Страница 10: ...Product dimensions 164 mm 36 mm 106 mm 100 mm 29 5 mm 100 mm Receiver H3747 Programmable Thermostat Display PTD 10...

Страница 11: ...ou are replacing an existing programmer or time switch or even performing a fresh installation we recommend that you install the Secure Installer Guide mobile app 11 2 Open the app and select Replace...

Страница 12: ...A1 1 2 Install the receiver 12 3 X X Fascia plate Mark out the position...

Страница 13: ...13 Drill the holes and secure the mounting plate A2 X X 1 M3 5 AB type screws 2...

Страница 14: ...In case of surface wiring Optional Note Perform this step only if you have surface wiring Break the surface wiring knockout provided on the receiver before proceeding further 14...

Страница 15: ...e 1 On 1 Zone 1 On 2 COM 1 2 COM 3 On 2 Zone 2 On 4 COM 3 4 COM 5 On 3 Zone 3 or hot water On 6 On 4 Zone 4 On Earth Backplate N L 1 2 3 4 N L 1 2 3 4 5 6 5 6 If replacing take a picture of your old t...

Страница 16: ...em A3 E N L Mains supply N L 1 2 3 4 5 6 Receiver back plate N L Boiler Zone 1 valve Zone 2 valve Zone 3 valve Zone 4 valve ON ON ON ON Call Call Call Call This diagram is schematic and should be used...

Страница 17: ...and hot water system A3 N L 1 2 3 4 5 6 Receiver back plate N L Boiler Zone 1 valve Zone 2 valve Zone 3 valve ON ON ON Call Call Call C Cylinder stat E N L Mains supply This diagram is schematic and s...

Страница 18: ...3 4 5 6 Receiver back plate N L Boiler Zone 1 valve Zone 2 valve Zone 3 valve Zone 4 valve ON ON ON ON Call Call Call Call C Cylinder stat A3 3 zone heating and hot water system This diagram is schem...

Страница 19: ...Plug in the WiFi extender HC2 4 optional 1 2 Remove dummy cover a b Plug in the WiFi adapter Note WiFi adapter once installed cannot be removed 19...

Страница 20: ...Fit the receiver A4 1 2 a b 20...

Страница 21: ...p It suggests that the receiver is ready to be paired with mobile app or another PTD 2 Use the bottom button Apply Boost to con rm channel selection Channel LEDs 1 2 3 4 Select channel Apply Boost Bli...

Страница 22: ...Install the PTD The PTD should be placed approximately 1 5 metres above oor level in free space away from draughts and sources of heat or electrical interference Ideal mounting location 1 5 m 22...

Страница 23: ...B1 1 2 X X Mark out the mounting position Unbox 3 The product is shipped in deep sleep mode to save battery To wake up the device you must press the button at the rear before setup Press 23...

Страница 24: ...Fit the PTD B2 X X 1 2 M3 5 AB type screws 3 Click a b 24...

Страница 25: ...or enter 1 To navigate between modes Home Away Press 2 To enter a menu screen or button Press 1 Increase the target temperature 2 To navigate between di erent menus In backwards direction 2 To naviga...

Страница 26: ...The PTD has great temperature sensitivity and you may observe a sudden rise in ambient temperature during the commissioning process triggered by the touch of your hand This is only temporary Long pre...

Страница 27: ...Establish communication with the receiver 27 Press or to select fuel type Press Home Away to con rm selection x1 Press or to select Yes or No Press Home Away to con rm selection x1...

Страница 28: ...Home Away Communication established PTD after establishing communication with the receiver 28...

Страница 29: ...Install the user mobile app 1 Download the Secure Controls user mobile app 2 Open the app and create an account to sign in 29...

Страница 30: ...Optional installation 1 Add new PTD 2 Add new Temperature Sensor THS Refer quick installation guide of PTD Refer quick installation guide of THS 30...

Страница 31: ...C Relay contact voltage rating Ch1 to Ch4 Volt free max 230 240 V AC Relay current rating 3 1 A maximum Relative humidity 0 to 95 non condensing Storage temp range 20 C to 70 C Wireless communication...

Страница 32: ...to 40 C 20 C to 70 C 0 to 95 non condensing Pollution degree Ingress protection Battery speci cations Battery life Wireless communication 2 IP30 Non replaceable 2x A Lithium ion 3 6 V 3600 mAh each 12...

Страница 33: ...CT400 000 SCS100 000 SCW100 000 and hot water Battery operated device for zone heating Mains powered 2 channel receiver C1727 and Programmable Thermostat Display PTD Mains powered 4 channel receiver H...

Страница 34: ...Notes 35...

Страница 35: ...for replacing traditional wired controls for systems that require separate control of heating and hot water or multiple heating zones The H3747 Smart programmer is designed for use with one to four z...

Страница 36: ...ecure Meters UK Ltd South Bristol Business Park Roman Farm Road Bristol BS4 1UP United Kingdom Bristol Phone 44 117 9788 700 UK Free Phone 08081687224 UK Direct 44 196 2826 225 support securemeters co...