Radio Key

®

 RK-65K                                           Operating Guide

Secura Key 

 

      1

INTRODUCTION

The Radio Key

®

 RK-65K is a programmable single-door access 

control system which controls access for up to 65,000 users.  It 
can control an electric strike, magnetic lock, or gate operator, 
and has an additional programmable input which may be set 
as a remote open input or as an LED/Beeper control for use 
with the Wiegand output.  A Wiegand output is also provided to 
allow for later upgrading to an on line system. Information on 
using the RK-65K as a Wiegand reader is contained on page 18 
The major components are shown in Figures 1 and 2. 

The Radio Key

®

 RK-65K Access Control Unit contains the CPU, 

memory, access relay, and an internal reader. It has a beeper, and 
a bi-color LED indicator. An RK-HHP Handheld Programmer or an 
RK-PD1 Program Deck (not included), is used to add or delete tran-
sponders, to set the operating mode, to program the password and 
latch timer. The Radio Key

®

 RK-65K is compatible with the Secura 

Key SecuRelay™, an intelligent relay module used to eliminate the 
possibility of break-in by attacking the access control unit.

The current version of this product also replaces the RK100M. 
The RK100M reads randomly encoded tags and supports only 
100 users. To convert this unit to RK100M mode, follow the 
instructions on Page 21.

Содержание RK-65K

Страница 1: ...5K RK 65KS with RK100M instructions STAND ALONE PROXIMITY ACCESS CONTROL SYSTEM with DYNASCAN TECHNOLOGY 3321732 Operating Guide Rev C www SecuraKeyStore com 800 878 7829 sales securakeystore com U S...

Страница 2: ...COPYRIGHT 2007 SOUNDCRAFT INC V060107 6451...

Страница 3: ...5KS 4 Programming Radio Key RK100M 5 Handheld Programmer RK HHP Programming Deck RK PD1 6 Programming Steps 7 Programming Hints 13 Basic Operation 19 Converting to RK100M Mode 21 Warranty 28 Speci cat...

Страница 4: ...page 18 The major components are shown in Figures 1 and 2 The Radio Key RK 65K Access Control Unit contains the CPU memory access relay and an internal reader It has a beeper and a bi color LED indica...

Страница 5: ...Secura Key 2 Figure 1 Radio Key RK 65K RK 65KS Units NOTE All references to RK 65K also apply to the RK 65KS Figure 2 Programming Deck RK PD1 Hand Held Programmer RK HHP NOTE Programming sequences are...

Страница 6: ...can order the same Facility Code specifying the starting number which will be one digit higher than your highest existing transponder If you use Format 201 these are shipped from stock and you may re...

Страница 7: ...tags and cards are pre encoded and engraved at the factory with a Facility Site Code and an individual card ID number You must teach the RK 65K which Facility Code or Codes up to 10 it should recogni...

Страница 8: ...ws you to assign a Transponder to each User ID Number 1 100 for programming purposes The User ID Number is associated with the individual person using the transponder Be sure to record the User ID Num...

Страница 9: ...ng cards ENTER 7 SEVEN 0 ZERO 8 EIGHT 1 ONE 9 NINE 2 TWO THRU 3 THREE VALID 4 FOUR VOID 5 FIVE SET TIMER 6 SIX MODE Presenting these cards to the Radio Key RK 65K is equivalent to pressing the identic...

Страница 10: ...the reader After you have completed a proper program sequence the unit will beep and the LED will ash green to indicate that the program instruction has been accepted A red light and a beep at the end...

Страница 11: ...asswords are entered the unit will sound an alarm and display a red LED for 30 seconds then return to normal mode Change your Password RK65K RK100M Put the unit into the Program mode if necessary See...

Страница 12: ...wn wire restore power The factory default 12345 is now in effect The LED will ash alternately Red and Green While this is occurring set the Facility Code or Codes in the reader see below Remove power...

Страница 13: ...reader one at a time After you are nished allow the reader to time out and return to the Normal Mode before proceeding NOTE An invalid facility code will beep with no LED visible ADDING AND DELETING U...

Страница 14: ...Then press Thru followed by the sequence of digits representing the highest transponder ID number Then press Enter For example to add transponders 1 through 10 to the system 1 1 0 Transponder number...

Страница 15: ...numbertransponder Finally press Enter For example to delete transponders 1 through 10 1 1 0 Transponders 1 through 10 are now void Set the Latch Timer RK65K RK100M Put the unit into the Program mode S...

Страница 16: ...have set an extended latch time but need to interrupt it follow this procedure Put the unit in Program Mode see Page 8 Then press Set Timer then 1 then Enter After the Program Mode expires present a...

Страница 17: ...remote open input will activate the relay for the time the latch timer is set Mode 2 deactivates the unit No tag can activate the relay but the remote open input will activate the relay In mode 3 the...

Страница 18: ...unit to the inactive locked mode the following sequence would be followed 2 To Exit Programming Mode Immediately RK65K RK100M Press MODE then 1 or 2 3 or 4 card to the unit Press ENTER This returns t...

Страница 19: ...he Program Mode see Page 8 Press SET TIMER then press THRU Press the digits representing the maximum number of minutes you want antipassback to apply 01 99 Press ENTER Antipassback can be from one to...

Страница 20: ...gate operator A normally closed relay is used for fail safe devices such as magnetic locks The Secura Key SecuRelay sold separately is a remote intelligent relay used to prevent entry when the access...

Страница 21: ...nput is set at the factory as a Remote Open input Connecting the brown and the orange wire usually with a push button switch will activate the relay for the time set for the latch timer This input may...

Страница 22: ...RK 65K Unit The Radio Key RK 65K Unit generates an RF eld which causes the Key Tag to transmit a unique Transponder ID Number back to the Unit If the Transponder ID Number is stored in memory the lat...

Страница 23: ...open input is activated the relay will activate When the remote open input is deactivated the relay will return to the inactive state after the latch timer times out A green light and a beep indicate...

Страница 24: ...0 users If you need to replace an existing RK100M or if you want a reader that uses random cards and tags you may convert this product to the RK100M mode as shown below In the RK100M mode some program...

Страница 25: ...the system as described below RadioKey 100MallowsyoutoassignaTransponder toeachUserID Number 1 100 for programming purposes The User ID Number is associated with the individual person using the transp...

Страница 26: ...r 12 the following sequence would be followed 1 2 Hold Key Tag or Card near unit Record the User ID Number and Transponder ID Number NOTE IfyouassignanewtranspondertoaUserIDNumberwhere another transpo...

Страница 27: ...d on the Transponder then press ENTER For example to program a Transponder ID Number 995 into User ID Number 12 the following sequence would be followed 1 2 9 9 5 Record the User ID Number and Transpo...

Страница 28: ...Transponders are already entered into the User ID Number range you have selected they will be overwritten For example to program ten transponders into User ID Numbers 1 through 10 the following sequen...

Страница 29: ...quence of digits representing the desired ending User ID Number Finally press ENTER A green light and beep mean that the range of Transponders was deleted 1 1 0 Delete a Transponder by Presenting to R...

Страница 30: ...s VOID Press THRU then press the sequence of digits representing the ID number printed on the Transponder Finally press ENTER A green light and beep means that the transponder was deleted For example...

Страница 31: ...SIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IMPLIED SECURA KEY SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES OR MERCHANTABILITYAND FITNESS FORAPARTICULAR PURPOSE The remedies pr...

Страница 32: ...40 mA Idle Wiegand Output Any Wiegand Format up to 40 bits Maximum Distance 500 Ft 5 or 6 conductor 20 gauge shielded cable Outputs SPST Solid State Relay 1A max 60 VAC or DC Normally open or normally...

Страница 33: ...numbered only Card Key Tag Operation Passive Transmit Frequency 125 kHz Memory Non Volatile Latch Timer Programmable 0 25 sec to 18 hours or Toggle Mode Accessories RK HHP Hand held Programmer RK PD1...

Страница 34: ...quipment off and on the user is encouraged to try to correct the interference by one or more or the following measures Reorient or relocate the receiving antenna Increase the separation between the eq...

Страница 35: ...www SecuraKeyStore com 800 878 7829 sales securakeystore com...

Отзывы: