Access Control Unit
MOV
Installation Instructions
Mounting Plate
2, #6 Mounting Screws
1, 4x40 Screw
1, Security Screw
1, Cable Assembly
ACCESSORIES (NOT INCLUDED):
RK-PS:
9VDC Plug-in Power Supply. It is designed
to power the Reader. Requires
110 Volts AC power.
SK-SR
SecuRelay™ - Smart Relay Module DPDT.
3322328 7744
20301 Nordhoff Street, Chatsworth, CA 91311
PHONE (818) 882-0020 • FAX (818) 882-7052
TOLL-FREE (800) 891-0020
www.securakey.com • [email protected]
INSTRUCTION TO THE USER
FCC ID: NNHETXXX
“This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.”
regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to
authority to operate this equipment.
WIRING CONNECTIONS
WIRE COLOR
RKDT-SR-M / SR-S
GREEN
Open Collector 1
WHITE
Open Collector 2
VIOLET
RS-485-B
GRAY
RS-485-A
ORANGE
Input 1
BROWN
Input 2
YELLOW
Input 3
BLUE
Input 4
RED
5-14VDC +
BLACK
DC Ground
WHITE/BLACK
RELAY
WHITE/BROWN
RELAY
SPECIFICATIONS:
RoHS
3059349
PARTS SUPPLIED:
POWER REQUIREMENTS
5-14 VDC, Avg. 200 mA
INDICATORS
LED
Tri-Color (Blue /Red /Green)
Buzzer
Host activated
INPUTS & OUTPUTS
Open Collector Rating 20 VDC @ 300 mA
Solid State Relay
60V max – 1.0A AC/DC
Inputs 1 – 4
Ground to Activate
ENVIRONMENT
Ambient Temperature
-40° to +70°C (-40° to +158° F)
Humidity
0 to 100% (non-condensing)
COMMUNICATIONS
RS-485
Host Driven Protocol
Cable Distance
4,000 ft. total system
Cable Type
2 twisted-pair, 22-24AWG
or CAT-5
party responsible for compliance could void the user’s
authority to operate the equipment”.
RF
915 MHz
“Changes or modifications not expressly approved by the