PCSC User Guide
Page 5
Hamster Pro Duo CL™ PCSC User Guide
2.2 PCSC Command-line Arguments
PCSC is invoked with three command-line arguments;
PCSC.EXE <reader> <delay> <test>
<reader> - The number of the enumerated reader
<delay> - The number of milliseconds to delay between smart card commands.
This must be an integer value greater than or equal to zero.
<test> - They type of card test to be performed.
M = Mifare and must be run with the PICC reader
S = SAM and must be run with the SAM reader
There is a special set of command-line arguments to be used in the case where both
readers are to be tested at the same time
PCSC.EXE 0 <delay> B
Reader=0 – Both readers will be tested
Test=B – Both SAM and MIFARE tests will be executed
3. TESTING THE MIFARE CARD
3.1 Place the MIFARE 1K card on the device.