Operating Instruction 

 
LC200 –Level Controller 200  
LC 201 – Level Controller 201  

SW 02.57 

05 2012    LC 2 E M 07_C 

Содержание LC 201

Страница 1: ...Operating Instruction LC200 Level Controller 200 LC 201 Level Controller 201 SW 02 57 05 2012 LC 2 E M 07_C ...

Страница 2: ...tice Safety Instruction Important LC must not be installed in a hazardous environment and must not be used for the following liquids Gasoline Ethanol aggressive chemical products like acids and aggressive chemicals Improper use and any resulting damages the manufacturer cannot take any responsibility Modifications on the product are prohibited Service repair and maintenance shall be done by the ma...

Страница 3: ...the tank as indication you should install at least a min distance of 5 cm from the wall to the aperture The indicator should be in a position where the ultra sonic pulses can beam unhindered to the bottom of the tank Built in parts can disturb the ultrasonic pulses and may result a false measurement e g pipe manhole cross beam Check the installation situation when the tank is empty because if the ...

Страница 4: ...r stocks to avoid problems e g an empty tank Take the time which you have saved with the LC device and control the tank continuous so that it is always in good order and condition Please note the legal requirements for your tank and if you have concerns ask a license specialty company Always take a look to the service intervals of your tank and a specialist licensed company should advise you that ...

Страница 5: ... if the measurement was launched by pressing the arrow button Selection of Tank Type 1 2 or 3 Start from the standard display press mode button 3 sec SET UP Starts Tank Typ1 cubic defined by height and tank capacity Tank Type 2 Cylindrical horicontal defined by height and tank capacity Tank Type 3 Cylindrical vertical defined by height and tank capacity Button Mode Display selection Button Set up ...

Страница 6: ...e Current time Hours and minutes 0757 Instant of time Measurement Time daily e g at 07 30 h measurement is made by LC200 GSM Mode GSM Mode 1 GSM enable 0 GSM disabled 1 SMS send according to operated settings GS sen SMS frequencies 0 every 28th of each month 1 every 7 days 2 every 14 days Tel No Receiver 1 Telefon Number Recipient No 1 Any modification e g 0167 78787787 or 0044 167 7878787 Tel No ...

Страница 7: ... a 90 against a plain surface floor wall or ceiling etc and press the arrow button to launch your first experience Mounting Installation LC 200 201 is equipped with two threads 1 5 Inch 6 4 und 2 Inch thread Use a free thread on top of the tank Take care that there is no obstacle between sensor and tank level for free ultra sonic beam Notice for your installation Parameters Tank Setting Tank Type ...

Страница 8: ...tion Available after 10 days before the error symbol E appears Proceed with Mode Temperature in C Temperature inside LC200 device Proceed with Mode Full distance sensor to sureface below 20 cm Error code figures from 0 to 3 0 no error 2 no correct measurement check LC 200 position 90 to surface is a must 3 measurement result not logical check settings Measured depth is higher than setup value inst...

Страница 9: ...t immediately and send a return SMS with the current measurement For remote measurement GSM must be registered LC 201 sends back to all registered phone numbers Remote control tank configuration Create a SMS on your cellular phone with the following format The S Message below is an example with some given Settings If the LC has received the S Message it will immediately send back a SMS with the ne...

Страница 10: ... after the actual time exit the configuration mode after 2min the LC200 launches a measurement and send a SMS SMS Massage Message order figures as examples 00805 tank content in litres 00080 tank content in percent 00195 ullage in Litres 0001 average consumption last 10 days 805 remaining days 039 measured distance in cm 022 ambient temperature in Celsius 062 Battery Voltage example digit is 57 5 ...

Страница 11: ...orised service facility If the device is damaged remove it immediately from your tank and send it to an authorised service facility If the device is removed close the tank entry after that so that the vapours can t escape Technical Data LC 200 Dimension w x d x h 130 mm x 65 mm x 160 mm LC 200 Battery 4 pcs 1 5V Baby Type C Alkali Battery life time appr 3 years in power safe modus at room temp LC ...