Universal GSM / GPRS communicator

Wiring  manual 

1

The  device  must  be  installed  in  a  place  with  limited  access.

Please act according to your local rules and do not dispose of your unusable alarm system or its components   with other household 
waste. This product   utilization in EU is covered by European Directive   2002/96/EC.

The device must be connected 

to an AC power supply with Protective Earthing. Cable colours mean: Phase or Live line (L) -   black 

or brown cable, Neutral line (N)   - blue cable, Protective Earth line (PE) - green cable with a vertical yellow dash. Double isolated 

2

cables with minimum cross-sectional area of   0,75 mm  for 230V power supply must be used. 

The device uses two power supplies: main and back-up.

2V, 7Ah/20HR capacity, rechargeable hermetically sealed Lead-Acid battery.

Main power supply: a   power   transformer   with:
       - primary winding: ~230V, 50 Hz; 
       - secondary winding: ~20V, 1.5A, 50Hz.
Back-up power supply: 1

GSV4M

 is compliant with   EN 60950-1 safety requirements.

P

ower supplies

 

described

 above

 must 

comply with the EN 60950-1 safety requirements.

All devices being connected with the alarm system (sirens, detectors, computer for programming and etc.) must comply with                   
EN 60950-1 safety requirements.

The 

communicator

 contains a radio transceiver operating within GSM900/1800 frequency ranges.

DO NOT USE the 

communicator

 where interferences can arise because of the influence 

with 

other devices

 and this may

 caus

e

 the 

potential danger.
DO NOT USE the 

communicator

 close to medical devices. 

DO NOT USE the alarm system device in a dangerous environment with the risk of fire and explosion. 

Additional 

automatic Two-Pole Circuit Breaker

 should be installed in an AC electric power circuit in order to protect against   

over-current, short circuits and earthing faults.
The circuit breaker contact gap should be no less than 3mm, protective circuit breaker   current must be   in   0,5A - 2A   range   .
The circuit breaker should be placed close to the system's housing and should be easily accessed.

Before performing any work of installation or service 

always

 disconnect the device from power supplies in sequence as described 

below:

  -  cut  off  

230 V

 AC power line with the automatic Two-pole Circuit Breaker

;

  -  disconnect 

12V back-up battery

 by removing battery female plug from Control Panel male socket BAT.

Two-pole Circuit-Beaker installation on flexible cables is forbidden.

General safety requirements

:

 - do not touch any part of the main power supply under voltage: transformer, a fuse block, connection wires;
 - it is forbidden to perform any device installation or service work during lightning;
 - use batteries according to manufacturer recommendations. The use of improper battery type may cause an explosion;
 -

be sure battery terminals are isolated, battery terminals short-wiring   may cause an explosion.

 

battery replacement : 

It is not recommended to connect the device to a fully discharged battery

.  

Inoperative or expired batteries should be recycled according to the local rules or   EU directives   2006/66/EC   and   93/86/EEC. 

Collection and separate utilization of waste battery is mandatory!

To avoid system malfunction use an adequate charger to 

charge a new or discharged battery before connecting battery to the   device.

The connection to the mains supply must be made as per the local authorities rules and regulations. 
The end of a stranded conductor shall not be consolidated by soft-soldering, insulated pins shall be used. Insulated pins shall be 
connected in a manner that they are and with remain mechanically efficient.

Power supply distribution board

Automatic two-pole 

circuit breaker

L

N

N

L

Cable from power 

distribution board

Power cable to the 

cabinet

The device 

installation

 and service should be performed by trained personnel with sufficient knowledge about the device and 

general safety requirements for work with low voltage (up to 1000V) AC power lines. 

In the case of a device malfunction repair 

works can be performed   by qualified   personnel   only. If the system is malfunctioning, the end user should inform the qualified   
personnel as soon as possible. User doesn't have right to repair the system.

GSV4M, installed in the metal cabinet (device)

Picture 1. 

Automatic two-pole circuit breaker and power cable wiring diagram

Universal GSM / GPRS communicator 

communicator

comes with in-built  LED indicator. LED blinks when 

 is powered up.

SAFETY  WARNINGS