Page 6

Page 7

Figure 4:

SECOPAGE 35E7 —
FOR USE AS A STAND-
ALONE BURGLAR ALARM

NOTE:

1

.

This method is suitable for the SECOPAGE 35E and SECOPAGE 35E7.

NOTE for the SECOPAGE 35E:

a.
No YELLOW wire (the alarm is powered on a 24-hour basis only).

b.
No BLUE/BROWN wire (no delayed zones).

2

.

This diagram is for an example only.  Other zones can be connected (up

to 6 zones for the SECOPAGE 35E7.)

3

.

Pager requires 1A of power during transmission.

4

.

The manual page button operates normally.

5

.

Minimum pulse length required to trigger:

a. SECOPAGE 35E: 1 second.

b. SECOPAGE 35E7: 100 msec.

6

.

ANTENNA MUST BE CONNECTED.

L1

C1

C2

Fuse (2A)

Battery

BLUE — Instant N.O. (-) trigger input

BLACK — Ground (-) input

RED — +12VDC (+) input

YELLOW — Arm/disarm input (GROUND to

arm, BREAK ground to disarm, or connect

directly to GROUND for 24-hour operation)

Figure 3:

PAGING WITH ZONE ANNUNCIATION

Paging

button

(-) N.O.

delay

zone

(-) N.O.

instant

zone

BLUE/BROWN — Delay N.O. (-) trigger input

Alarm control panel or

communications panel

BLUE / WHITE

 — Instant N.O. (-) trigger input

BLUE / GREEN

 — Instant N.O. (-) trigger input

PURPLE / BROWN

 — Delayed N.O. (+) trigger input

WHITE / RED 

— +12VDC (+) siren output, (max 1A)

RED 

— +12VDC (+) input (via supplied 2A fuse)

BLACK 

— Ground (-) input

BLUE / BROWN 

— Delayed N.O. (-) trigger input

L1

C1

C2

Strip 

antenna

(E-35ANT)

CB 

antenna

YELLOW*

  — Arm/disarm input (GROUND to arm, BREAK ground to disarm)

t

PURPLE

 — Instant N.O. (+) trigger input

BLUE

 — Instant N.O. (-) trigger input

BLACK / WHITE

 — Paging push-button, N.O. switch

NOTE — CONNECT CB

ANTENNA OR STRIP

ANTENNA BEFORE

TESTING THE UNIT.

For optimum transmission
range, adjust L1, C1, & C2
after connecting antenna.
(See "Connecting and Tuning
an Antenna."

* NOTE regarding the

YELLOW  wire — To arm
the alarm, apply ground to
the YELLOW wire (there is
a 60-second delay before
the alarm arms).  To
disarm, break the ground.

t

Antenna jack

Paging
button

Fuse (2A)

+12VDC power
supply and battery

*
*
*
*

*
*

*

N.O. switch (magnetic

contact, push-button, etc.)