background image

Installation:

1. Determine where the deadbolt will be mounted (see fig. 1).

2. Adjust the wire output direction based on the selected application and adjust the lock delay time if

necessary (see fig. 3).

Adjust the wire output direction

a. Unscrew the 2 screws and remove the cover of the lock body.

b. Remove the wire grommet from the lock body and insert the wires of the 5-pin connector into the

grommet .

c. Plug the 5-pin male connector  into the 5-pin socket and adjust the desired wire output direction as

shown in fig. 3.

Adjust lock delay time

a. The default lock delay time is 3s. To remove the delay time, remove the jumper (see fig. 3).

3. Use the screw holes of the lock body and strike body as template and mark the locations of the screws

with a pencil.

4. Secure the lock body and strike body with the 6 included screws. Use 4 screws for the lock body and 2

screws for the strike body. Cover the screw heads with the provided screw cover stickers.

Note:

If there’s a gap betweent the lock body and the strike body, use the included 2 plate spacers to correct

the alignment as shown in fig. 2.

5. Connect the wires and insulate them (see fig. 4):

a. Red – Power input (+)

b. Brown – Power input (-)

c. Green – Control wire (-) ground to release bolt

d. Blue – Door monitor, COM

e. Purple – Door monitor, N.C. (active when door closed)

Warning

 :

1. Correct polarity of the red and brown wires is critical.  Incorrect polarity will burn out the solenoid .

2. Do not connect a voltage input on the green wire otherwise it will damage the unit.

3. Maximum distance between lock body and strike body must not exceed 6mm.

3

2

Mini Surface-Mount Deadbolt Manual

SECO-LARM U.S.A., Inc.

SECO-LARM U.S.A., Inc.

Introduction:

The SECO-LARM Mini Surface-Mount Electric Deadbolts is designed for hollow metal door frames and solid

wooden door frames. Its small size makes it easy to add secure, electrical locking to small doors.

Specifications:

Fig. 1 – Possible Mounting Locations.

Fig. 4 –Wiring Diagram

Fig. 2 – Using the Plate Spacers

Card reader

or keypad

COM

N.C.

N.O.

Request-to-Exit

pushbutton

Purple wire (Door Monitor, N.C.) – active if door is locked
Blue wire (Door Monitor, COM) – manual lock/unlock

Red wire (+)

Brown wire (-)

Green wire (Control wire)

12VDC

Power

Supply

Fig. 3 – Adjusting the Lock Delay Time / Wire Output Direction.

Adjust wire grommet for

different wire output direction

Lock delay jumper

5-Pin Connector

5-Pin Socket

Jumper

ON

Plate spacer

Vertical mount

Horizontal mount

Strike body

Lock body

Mini Surface-Mount Deadbolt Manual

Delay Time

3s (default)

0s

OFF

1x Lock  body

1x Strike  body

2x Plate  spacer

Parts List:

1x 5-pin  connector

6x Mounting screws (M4x40mm)

6x Screw cover stickers

Lock body

Strike body

Plate spacer

Overview:

Operation
Operation voltage

Current draw

Status sensor
Adjustable lock delay timer
Operating Temperature
Weight

Standby
Active

250mA@30VDC (NC/COM)

Fail-safe

12VDC

237mA@12VDC max.
650mA@12VDC max.

0/3 s (default)

32°~158° F (0°~70° C)

1-lb,2.5-oz (450g)

Отзывы: