NOTICE: 

The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves 

the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the 
property  of  SECO-LARM U.S.A., Inc.  or  their  respective  owners.  Copyright © 2020  SECO-LARM U.S.A., Inc.  All  rights 
reserved.  

WARRANTY:

 

This SECO-LARM product is warranted against defects in material and workmanship while used in normal 

service  for  1 year  from  the  date  of  sale  to  the  original  customer.  SECO-LARM’s  obligation  is  limited  to  the  repair  or 
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if 
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper 
or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not 
operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM 
and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event 
shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind 
to the purchaser or anyone else. 

Bracket kits for SD-993B-SS  
Electric Shear Lock 
If the shear lock does not activate when 
the door is closed

 

 

The magnet assembly is too far away from the armature 
assembly.  

 

Adjust the distance between the magnet and armature 
assembly by adding more shims under the back portion of 
the armature assembly. 

 

Re-adjust the position of the armature assembly or the 
magnet assembly. 

Poor attraction between the magnet 
assembly and the armature assembly 

 

Check the power supply, and make sure it is according to 
specifications. 

 

If the power supply is adequate, replace the unit. 

If the magnet assembly pulls the 
armature assembly, but the door can 
still be opened 

 

Check to make sure the locking bolts are in the armature 
assembly’s keeper hole when the unit is activated. 

If the door can be kicked in or pushed in 
with your shoulder 

 

Check to make sure the magnet assembly and armature 
assembly surfaces are clean and free from dirt.  

 

Even a little dirt could reduce the attraction between the two 
surfaces. 

For any other problems 

 

Test again 

 

Replace the unit 

 

The problem unit can also be substituted for a working unit in 
another door frame to see if it works there. 

 

 

PITGW1 

 

MI_SD-993B-SS_200909.docx 

SD-993S-SB 

Surface-Mount Bracket Kit 

SD-993S-UB 

U-Bracket (Glass door) Kit 

 

 

 

Accessories:  

Содержание SD-993B-SS

Страница 1: ...ssory which are installed in accordance with the manufacturer s installation and operation instructions ANSI NFPA 70 and the local authority having jurisdiction Holding Force has not been verified by...

Страница 2: ...Destructive attack Level I Line security Level I Standby power Level I Endurance Level IV Static force 1 500 lb 680kg Dynamic force 70 ft lb Endurance 250 000 cycles Operating temperature 32 120 F 0 4...

Страница 3: ...ill show where the door rests relative to the door frame when it is closed d Measure and trace a line between these two lines This is the door frame center line IMPORTANT Make sure the place you choos...

Страница 4: ...r line you just drew For Hollow Metal Doors 1 Cut out the rectangular piece of metal as shown on the door template 2 Drill the four holes two on each end as shown on the door template 3 Using the incl...

Страница 5: ...me and the armature assembly onto the door 3 Use washers or flat pieces of metal to act as shims as necessary to mount the magnet assembly and armature assembly flush with surface 4 Close the door and...

Страница 6: ...or Use 1 x surface mount bracket The magnet assembly is in the bracket above the door and the armature assembly is in the bracket on the door The magnet assembly is flush to the door frame or header a...

Страница 7: ...ing SD 993S UB May require 1 or more SD 993S SB and SD 993S UB bracket kits depending on the glass door configuration NOTES One glass door with a glass frame illustrated above Glass Frame 2x Surface m...

Страница 8: ...e limited to the replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damage of any kind t...

Отзывы: