background image

ENFORCER Video Surge Protector 

 2   

                                                             SECO-LARM U.S.A., Inc.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The ENFORCER Video Surge Protector is a passive device that helps prevent damage to sensitive 
CCTV equipment from power surges or lighting strikes. The device can be deployed in new 
installations or added to existing installations.  

 

The ENFORCER Video Surge Protector should be installed between a camera and a digital video 
recorder or video splitter to protect against surges that could damage video equipment. 

 

NOTE: For the best protection, it is recommended that two video surge protectors be installed, one 
near the camera, and one near the DVR.

 

 

Introduction: 

 

 

Bandwidth 

0~1GHz 

Maximum input 

1.0Vp-p 

Insertion loss 

<0.2dB 

Return loss 

16dB @ 75Ω 

Frequency response 

0-3dB at 10MHz 

Isolation voltage 

600VDC (min.) 

Insulation resistance 

10,000 MΩ 

Maximum surge voltage 

4KV 

Surge life 

300 surges @ 100A 

Surge protection time 

1ns 

Surge resistance 

Approx. 0Ω 

Power passing capability 

130 VAC/DC, 65 V

RMS

 @ 10A 

Connector 

In 

BNC Male 

Out 

BNC Female 

Impedance 

75 Ω (BNC-to-BNC) 

Dimensions 

3

1

/

16

” x 1” x 1” (78 x 25 x 25 mm) 

Cable length 

16” (406mm) 

Weight 

2.3-oz (65g) 

Enclosure material 

Aluminum 

Operating temperature 

32° ~ 131°F (0° ~ 55° C) 

 

Specifications: 

 

 

Installation: 

 

 

1.

 

Detach the video cable BNC connector from the camera BNC connector. 

2.

 

Attach the equipment end (male connector) of the first video surge protector to the camera BNC connector. 

3.

 

Attach the video cable BNC connector to the cable end (female connector) of the first video  
surge protector. 

4.

 

Connect the ground wire from the first video surge protector to an earth ground. 

5.

 

Detach the video cable BNC connector from the DVR/Multiplexor BNC connector. 

6.

 

Attach the cable end (female connector) of the second video surge protector to the video cable  
BNC connector. 

7.

 

Attach the DVR/Multiplexor BNC connector to the equipment side (male connector) of the second video 
surge protector. 

8.

 

Connect the ground wire of the second VS-1V12BQ to the metal chassis of the protected equipment. 

 