SECO-LARM ENFORCER HL Series Скачать руководство пользователя страница 4

ENFORCER One- and Two-Channel 917MHz RF Receivers 

4  

                                                      SECO-LARM U.S.A., Inc.  

 

 

 

 

 

 

 

 

Sample Applications: 

WARRANTY: 

This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for 

one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or  replacement of any 

defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed 

to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or 

if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects 

in  material  and  workmanship.  The  sole  obligation  of  SECO-LARM  and  the  purchaser’s  exclusive  remedy,  shall  be  limited  to  the 

replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or 

consequential personal or property damage of any kind to the purchaser or anyone else. 

NOTICE:

 The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right 

to  change  specifications  without  notice.  SECO  LARM  is  also  not  responsible  for  misprints.  All  trademarks  are  the  property  of 

SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2020 SECO-LARM U.S.A., Inc. All rights reserved.  

 

 

SECO-LARM

 

®   

U.S.A., Inc.

 

16842 Millikan Avenue, Irvine, CA 92606 

Website: www.seco-larm.com 

Phone: (949) 261-2999  |  (800) 662-0800  Email: [email protected] 

 

®

 

PITSW1 

762-151% 

MI_HL-951xx-SQ_201029.docx 

 

Typical N.C. Application 

Typical N.O. Application 

 

FCC COMPLIANCE STATEMENT   

FCC ID: K4E951T4 

THIS  DEVICE  COMPLIES  WITH  PART  15  OF  THE  FCC  RULES.  OPERATION  IS  SUBJECT  TO  THE  FOLLOWING  TWO 

CONDITIONS:  (1) THIS  DEVICE  MAY  NOT  CAUSE  HARMFUL  INTERFERENCE  AND  (2) THIS  DEVICE  MUST  ACCEPT  ANY 

INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 

Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to 

operate the equipment. 

IMPORTANT  NOTE:  To  comply  with  the  FCC  RF  exposure  compliance  requirements,  no  change  to  the  antenna  or  the  device  is 

permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s 

authority to operate the device. 

Model

 

HL-951R1-SQ 

HL-951R2-SQ 

Operating frequency 

917MHz* 

Memory capacity  

99 transmitter button codes per channel 

Operating voltage 

10~24 VAC, 9~48 VDC 

Operating 
current 

Standby 

7mA@12VDC / 5mA@24VDC (typical) 

Active 

50mA@12VDC / 25mA@24VDC per channel 

Relay 
Output 

Type 

Independent, sequence, access control 

Modes 

1~99 sec momentary (default, 1s), 1~99 min momentary, toggle, latch, follow (validity)  

Relay 

contacts  

Number 

Rating 

Form C 10A@14VDC 

Digital Display 

2-Digit, 7-segment LED 

Connectors 

Screw terminals, +, -, with NO/NC/COM per relay 

Operating temperature 

-40°~167° F (-40°~75° C) 

Dimensions 

3

15

/

16

"x2

1

/

2

"x1

3

/

16

" (100x63x30 mm) 

*

868.35MHz versions also available 

 

Specifications: 

Forward/Reverse, 2 Relays 

COM2 
NC2 
NO2 

Power 
GRD 

– 

Power  

12VDC 

Ch. 1 

Electric Door Strike 

Ch. 2 

COM1 
NC1 
NO1 

COM2 
NC2 
NO2 

Power 
GRD 

– 

Power  

12VDC 

Ch. 1 

Ch. 2 

Electromagnetic Lock 

COM1 
NC1 
NO1 

COM2 
NC2 
NO2 

Power 
GRD 

– 

Power  

12VDC 

Ch. 1 

Ch. 2 

Motor 

– 

COM1 

NO1 

NC1 

Отзывы: