 ELECTROMAGNETIC LOCK Installation Manual

ELECTROMAGNETIC LOCK Installation Manual

+

Status Sensor Output

N

O

SPDT rated 3A @ 12VDC

}

Control

Device

Power

Supply

+

Re

la

y

Status LED*

Timer

Adjust

COM

N

C

Voltage

Selection

Jumpers

Filler
Plate*

Standard
Mounting

"Z"
Bracket

For Inswing Doors

"L"

Bracket

*

Note: may require more

than one filler plate.

MOUNTING THE E-941SA-1K2PD

FIG.

1

FIG.

2

A. Drill holes for the mounting plate and

armature plate (see fig. 1 and 2) by
doing the following:
1. Fold the mounting template along

the dotted line.

2. Close the door. Find a mounting

location on the door frame near the
upper free-moving corner of the
door, as close to the corner of the
door frame as possible.

3. Place the template against the door

and frame.

4. Drill two holes in the door frame and

three holes in the door as indicated
on the template.

NOTE — A filler plate or an L-bracket or
Z-bracket (optional) may be required for
the electromagnet, depending on the door
frame.  See fig. 1.
B. Mount the armature plate to the door

using at least two steel and one rubber
washer (fig. 2):

NOTE — Actual installation varies
according to door style.

1. Put one rubber washer between two

steel washers, and place them over
the armature screw between the
armature plate and the door.  This
will allow the armature plate to
pivot slightly around the armature
screw in order to compensate for
door misalignment.

2. Tighten the sexnut bolt enough so

the armature plate can withstand
the force of someone attempting to
break down the door while the
electromagnet is engaged.

3. Do not tighten the armature plate

against the door.  The plate must be
able to pivot around the armature
screw.

4. Make sure the anti-spin guides are

in the two guidepin holes.

C. Screw the mounting plate to the door

frame or optional bracket:
1. Screw the two short self-tapping

screws in the slotted holes of the
mounting plate and adjust the
position of the mounting plate so
that it and the armature plate form
a 90-degree angle.

2. Once the position is correct, use the

long self-tapping screws to
permanently mount the bracket.

3. Remove the two short screws.

D. Drill the cable access hole.
E. Mount the electromagnet to the door

frame (fig. 1) — Use the Allen
wrench to screw the socket-head
mounting screws through the bottom
of the electromagnet into the
mounting bracket.

F. Connect the power leads (fig. 3):

1. Open the electromagnet.
2. Run two power leads from the power

supply through the cable access
hole into the electromagnet.

3. Connect the power leads to the

terminal block.

4. Close the electromagnet.

G. Test the unit.
H. Insert the tamper caps into the

mounting screw access holes.  This
should be the last step, as once the
tamper caps are in place, they will be
difficult to remove.

SECO-LARM U.S.A., Inc.

Page 2

Page 3

Voltage Selection

12VDC

Magnet set for 12VDC

operation as supplied

from factory.

Position a jumper over

the two middle pins for

24VDC operation.

24VDC

FIG. 3: 

Status

Sensor Output -

Connect to an alarm

panel or other

monitoring device.

Status Sensor Output — Monitors whether

the protected door is open or closed.
N.C. — Door opened, red LED on.
N.O. — Door closed, green LED on.
Relay — 3A @ 12VDC.

* Status LED — Indicates

whether the magnetic lock
is locked or unlocked.
Green — Locked
Red — Unlocked
Off — No power

Adjustable Timer Delay — For

1~78 seconds, turn clockwise

to increase time.  Timer starts

when power is applied.

E-941SA-1K2PD

SECO-LARM