28
Sed 64
4way I /O
Inputs x 4
Outputs x 4
Part :Sed 64 4 way I/O
Extra 4 relays and inputs
that can be multi chained
6.3
SED-64 Board options - 4 way I/O
This board allows for
an extra 4 inputs and 4 outputs
operating from the SED-64 v009
onwards
NC C NO
FAULT
Con
1
Earth 16vac +Batt -
Volts
TEST
PROG
PS
T
N
C 1 2 C 3 4
ZONE INPUTS
Line Fail LED
AC
sim card holder
SED-64
STATUS
WAKE
serial
prog
volts
5
4
3
2
1
0
9
8
7
6
FLT
OH
PWR
ZONE FAULT
LOW BATT
SIGNAL
STATUS
1 2
RS232
SED 64
4-way I /O
Inputs x 4
Outputs x 4
Part :SED 64 4-way I/O
10 WAY
RIBBON
LEAD
INSTALLATION PROCESS
1/ Power down the SED-64
2/ Fit Card as shown
3/ Fit 4 X 10k EOL into Inputs
4/ Power up
5/ Dip switches
The 4 zones can be tested thru and should come thru as zones
Point Number 258 to 261 see page 2.10 for details
Relays on this board are now controlled via SMS
Relay 1 = out5on
Relay 2 = out6on
Relay 3 = out7on
Relay 4 = out8on
See section 2.9 relay control for more functions