Short   overview   

 

Secabo   Thermobase   TB7   40cm   x   50cm   

 

● Heated   bottom   plate   as   extension   for   your   40cm   x   50cm   Secabo   models   like   TC7   SMART,   

TS7   SMART,   TPD7   and   TPD7   PREMIUM.   

 

● Better   print   results,   especially   with   sublimation   and   white   toner   transfers.   

 

● Particularly   suitable   for   sensitive   textiles   

 

● The   temperature   of   the   TB7   is   controlled   by   its   own   Secabo   controller.   

 

● Simple   mounting,   also   on   quick   exchange   system   and   slide   extension    

  

● Heats   quickly   up   to   a   temperature   of   160   °C    

  

 

 

Safety   Precautions   

 

Please   read   the   information   and   safety   precautions   carefully   prior   to   first   commissioning   of   the   
device!   

 

 

 

● Never   touch   the    heating   plate   with   your   hands   when   it   is   connected   to   the   power   supply,   

especially   when   it   is   switched   on   and   heated   -   danger   of   burns!   

 

● When   replacing   the   standard   base   plate,   make   sure   that   the   TB7   is   no   longer   connected   to   

the   power   supply   and   that   the   TB7   has   cooled   down   completely   -   risk   of   burns!   

 

● Never   open   the   TB7   and   the   corresponding   controller   and   do   not   make   any   changes   to   

both   components   yourself.   

 

● Should   it   be   necessary   to   open   the   heat   plate   cover   upon   explicit   request   by   Secabo's   

customer   service   team,   it   is   recommended   you   wear   respiratory   protection   and   only   touch   
the   insulation   wool   located   therein   using   gloves.   Possible   disposal   of   the   insulation   wool   
should   only   be   done   inside   a   closed   bag   

 

● Ensure   that   no   liquids   or   metal   objects   get   inside   the   TB7   and   the   controller.   

 

● Ensure   that   the   outlet   used   is   earthed.   Please   note   that   the   TB7   may   only   be   operated   at   a   

socket   which   is   protected   by   a   residual   current   circuit   breaker.   

 

● Disconnect   the   TB7   from   the   mains   when   not   in   use.   

 

● Always   operate   the   TB7   out   of   the   reach   of   children   and   never   leave   the   switched-on   

device   unattended.   

 

● Make   sure   that   the   TB7   is   only   used   in   dry   rooms.   

 

 

 

If   you   cannot   comply   with   one   or   more   of   the   aforementioned   safety   rules,   or   if   you   are   
unsure   as   to   whether   you're   in   compliance   with   all   of   the   points,   please   contact   our   
technical   support.   

 

 

 

 

 

 

 

 

 

Secabo   GmbH     Hochstatt   6-8     85283   Wolnzach     Germany     [email protected]     www.secabo.com   

 

Содержание TB7

Страница 1: ...your device Any form of reproduction of these operating instructions requires the written permission of Secabo GmbH Technical data and product features are subject to change without notice Secabo Gmb...

Страница 2: ...en the TB7 and the corresponding controller and do not make any changes to both components yourself Should it be necessary to open the heat plate cover upon explicit request by Secabo s customer servi...

Страница 3: ...le f Secabo TC Smart Base not part of the delivery contents just as an example Technical data Brand Secabo Work surface size 40 x 50 cm max temperature 220 C Power supply Wechselspannung 230V 50Hz 60H...

Страница 4: ...Items included Heating plate with silicone mat and coating Secabo GmbH Hochstatt 6 8 85283 Wolnzach Germany mail secabo com www secabo com Controller Box with table holder C13 Cold device cable...

Страница 5: ...or the Secabo Slide extension Place the table holder for the controller box on a flat surface near the TB7 and mount the controller box in it Attach the large 5 pin plug from the bottom of the TB7 to...

Страница 6: ...Display components and their meaning Secabo GmbH Hochstatt 6 8 85283 Wolnzach Germany mail secabo com www secabo com Area for time setting and countdown when press is closed irrelevant for the TB7 ti...

Страница 7: ...3 Wolnzach Germany mail secabo com www secabo com Area for time setting and activity indicator of the pre press feature irrelevant for the TB7 time is controlled by the heat press Icon for the Bluetoo...

Страница 8: ...scrolls across the display for 3s instead of the current temperature is activated when the CURRENT temperature corresponds with the TARGET temperature allowing for a certain deviation of X Arrow up is...

Страница 9: ...mode ends automatically Pressing will exit the input mode the display will return to its original value Pre pressing can be activated permanently from the settings menu More information below Saving t...

Страница 10: ...tooth 3 Bluetooth PIN for TB7 please deactivate do not use You can use the rotary knob to save your individual PIN which the app will then prompt you to enter The default PIN from factory is 255 which...

Страница 11: ...rolled by the heat press Press the button for 2s display flashes briefly values are set to 0 Second setting tier for operational key figures and service Press and hold the Settings button to enter the...

Страница 12: ...work should be carried out with the press switched off and cooled down The plug must first be removed from the socket Carry out maintenance work only after consultation with our technical support The...

Страница 13: ...inishing processes After the press operation garments must cool off before any carrier media can be pulled off the transfer material The hot glue in the transfer material doesn t develop its adhesive...

Страница 14: ...ns of the following EC Directives and Harmonized Standards EG Richtlinien EC Directives 2014 35 FG Niederlassungsrichtlinien 2014 35 EC Low Voltage Directive 98 37 EG Maschinenrichtlinie 2006 42 EG ab...

Отзывы: