Seca 769 1321004 Скачать руководство пользователя страница 13

Service Manual 

 

 Spare parts list 

 

seca 769 LC / 799 LC electronic 
Item Articel-no.  Designation 

Price 

stage 

 

23.11.2010/Rei 1 

30-34-00-746b 

Baseframe drawing page 3,  

 
01 

02-01-03-386-509 

Frame complete, calibrated mod.769 / 780 

42 

 

02-01-03-392-509 

Frame complete, calibrated mod. 799 

42 

 
02 

01-13-05-002-009 

Foot complete mod. 769 / 780 

05 

 01-10-04-007-009 

Foot 

complete for levelling mod. 799 

10 

 
03 02-03-03-298-807 

Platform 

25 

 
04 

01-13-04-223-009 

Platform mat  

20 

 
05 08-06-14-239-009 

Battery 

compartment 

15 

 
06 66-30-60-010-009 

Battery 

holder 

10 

 
07 02-11-03-011-009 

Roller 

complete 

18 

 
08 

02-01-03-130-509 

Column connection complete 

26 

 
09 01-13-05-270-009 

Plug 

white 

01 

 
10 02-01-03-383-009 

Counter 

plate 

10 

 
11 08-06-12-249-009 

Load 

cell 

28 

 
12 01-17-01-204-009 

Bubble 

level 

15 

 
 

Display housing drawing page 4 

 
21 04-02-06-215-008 

Column 

painted 

34 

 
22 34-02-01-001-009 

Display 

housing 

26 

 
23 

34-02-04-394-009 

Membrane keyboard mod. 769 / 780 

25 

34-02-04-404-009 

Membrane keyboard mod. 799 

25 

 34-02-04-405-009 

Membrane 

keyboard mod. 799 China 

25 

34-02-04-417-009 Membrane 

keyboard mod. 799 Japan 

25 

 
24 

08-04-04-195-509 

LC display pre-assembled 

37 

for mod. 769 

from  ser. no. 5 769 184 07 XXXX 

 

 

to      ser. no. 5 769 349 07XXXX 

 

 

for mod. 780 

from  ser. no. 5 780 184 07 XXXX 
to      ser. no. 5 780 349 07 XXXX    

 

 

 

08-04-04-195-009 

LC display pre-assembled (new software) 

37 

 

for Mod. 769 

models from ser. no. 5 769 350 07 XXXX 

for Mod. 780 

models from ser. no. 5 780 350 07 XXXX 

for Mod. 799 

all models 

 

for Mod. 869 

all models 

 
25 

34-02-01-262-009 

Connection piece left 

02 

 
26 

34-02-01-263-009 

Connection piece right 

02 

 
27 

14-05-01-917-509 

Sticker for window Mod. 769 / 780 

05 

14-05-08-220-509 

Sticker for window Mod. 799 

05 

14-08-08-240-509 

Sticker for window Mod. 799 Japan 

05 

 
 08-06-16-142-119 

Modular 

cable 1,0 m, 4-pole 

15 

 

 

Содержание 769 1321004

Страница 1: ...l technology Valid as of 01 12 2010 Variants Description LC2 electronic 30 34 00 745 Content Function diagram 25 02 02 281 Adjustment model spezific options 30 34 00 743 Description of faults 30 34 00...

Страница 2: ...Scale service Switch on off logics Display representation A maximum of five digits as well as some special characters can be displayed which can appear as shown below Explanation of the special charac...

Страница 3: ...hort circuited by means of a jumper switch Access to these contacts can only be gained by destroying the seal and opening the display housing After placing the jumper switch on the scale to start scal...

Страница 4: ...against reading out and modifying data via the programming interface Any modification of the data first requires that both memories are completely cleared Fault handling If faults occur they are disp...

Страница 5: ...he operation of the scale Temperature measurement In order to compensate for the load cell s temperature drift the temperature is measured regularly and the measured value is adjusted accordingly For...

Страница 6: ...es in the module The following memory types are provided Type of memory Size Flash memory 8 Kbytes EEPROM 512 bytes The flash memory holds the firmware for the microcontroller During programming the d...

Страница 7: ...ledged The module has a function for subsequent corner correction so that it is not necessary to re adjust the entire scale if a load cell is replaced To carry out subsequent corner correction two loa...

Страница 8: ......

Страница 9: ...equired 1 Switch on the scale and check the battery status If the battery voltage is low either the early battery warning symbol or the bAtt display is activated If one of the two displays occurs befo...

Страница 10: ...culated and saved Shortly afterwards the text Sto is displayed on the LCD and the scale automatically switches off some seconds later 8 Then remove the weight from the scale return the slide switch on...

Страница 11: ...to the sensor is interrupted Check the base frame for damage or incorrect assembly Scale shows only the segment test or the readings are varying to much Shortcircuit between sensor cable and housing...

Страница 12: ......

Страница 13: ...awing page 4 21 04 02 06 215 008 Column painted 34 22 34 02 01 001 009 Display housing 26 23 34 02 04 394 009 Membrane keyboard mod 769 780 25 34 02 04 404 009 Membrane keyboard mod 799 25 34 02 04 40...

Страница 14: ...ng page 5 38 19 17 02 218 009 Headpiece tongue 22 39 19 17 02 219 009 Headpiece plate 20 40 19 17 01 324 009 Sliding block 19 41 19 17 02 211 009 Slide guide left 03 42 19 01 02 212 009 Slide guide ri...

Страница 15: ...b HAMBURG Gepr ft APPROVED Ver b Datum Name PROJECTION R Archiv_DBWORKS Firma 30 30 34 30 34 00 746 03 nd Mitteil CHANGE 1 2 CONTENTS RESERVED Alle Rechte an und aus diesen Spare parts list mod 769LC...

Страница 16: ...diesen pos hinzu Spare parts list mod 769LC 799LC 30 34 00 746 04 R Archiv_DBWORKS Firma 30 30 34 30 34 00 746 04 Freitag 8 Januar 2010 15 09 57 Blatt SHEET 4 4 Gepr ft APPROVED Ver b Erstellt DRAWN...