I Introduction
After removing the unit from its packaging and ensuring that it has suffered no damage in shipment, it
is important to read this manual and follow its instructions to ensure proper connection and mounting.
711HS Series models are fully isolated dc-dc converters capable of delivering up to 720 Watts in
extreme ambient temperatures and adverse operating conditions. See specification sheets at the end
of this manual for the ratings of a particular model.
II Installation
2.1 Mounting
The converters are designed to be mounted to flat metal surfaces offering optimum heat transfer from
the converter base in environments where air flow may be restricted. For best results, thermal
transfer compound is a recommended interface between the converter and mounting surface. The [4]
mounting slots in the flanges will accommodate mounting hardware up to ¼ inch diameter. (See
figure #2 for mounting centers)
2.2 Connections
The Input/Output connectors on the converter is shown in Figure 1/1A with designated pin functions.
A - Positive Sense
B - Negative
C - Negative Sense
D - Positive
E - Housing Ground
A - Input Negative
B - NC
C - Remote Enable
D - Input Positive
F - NC
A
B
C
D
E
F
Input
A
B
C
D
Output
ON
OFF
ON-OFF switch feature on BK Model
Figure 1
Figure 1A
An option for users who wish to purchase a manufactured cable assembly is P/N 68-0711-8 which is
of 8 feet length and is a standard SEC part.
Page 1
Input side mating connector
Canon P/N 3106E20-8SB
Output side mating connector
Canon P/N 3106E20-24PB
PIN Max. Wire Gauge
A, D #8
C, E
#12
PIN Max. Wire Gauge
B, D #8
A, C
#12
Содержание 711HS Series
Страница 8: ...Page 6...