IV  User Adjustments 

 

700HS Series units are gasket-sealed. Changes or adjustments to the operating modes of any unit 
are accomplished internally:  

 

1)  To gain access, remove the 4 corner screws retaining the front connector plate as shown in 

Figure #4. 

 

 

 

2)  Proceed to raise the front plate by pulling the edge, next to the mounting surface, upwards until 

the view in Figure #5 can be attained.  

 

 

With P/N ATC 30

Replace Fuses

ATC 30

1 2 3

jumper 2,3 - Unit ON

jumper 1,2 - ON by Remote Pin

Output Voltage 

Adjustment

jumper

P1

CON1

F1,2,3

 

Figure 5 

Accessible Adjustments: 
 

A) 

Output voltage

 is trimmed by adjusting the potentiometer P1.  

B) 

Remote “Turn On” Disabled:

  Units are shipped from factory with pins 2 and 3 of the 

connector [CON1] jumpered as shown. This programs the unit to be “ON” when source power 
is applied.  

C) 

Remote “Turn On” Enabled:

  To program the unit for remote enable, shift the jumper from 

pin positions 2 and 3 of [CON1] to positions 1 and 2. In this mode the unit will energize when 
pin H is connected to the negative input line pin F.  

Page 3 

Figure 4 

Содержание 700HS Series

Страница 1: ...SEC SEC America LLC www secamerica com USER MANUAL 700HS Series DC DC Converters Applies to Models 721HS 737HS 749HS Aug 15 2015...

Страница 2: ...F CONTENTS page I Introduction 1 II Installation 1 2 1 Mounting 1 2 2 Connections 1 2 3 Mechanical Drawing 2 III Remote Sense Regulation 2 IV User Adjustments 3 IV Warranty 4 V Electrical Specificatio...

Страница 3: ...ed For best results thermal transfer compound is a recommended interface between the converter and mounting surface The 4 mounting slots in the flanges will accommodate mounting hardware up to inch di...

Страница 4: ...th the voltage at the end of the cable may be noticeably lower than at the terminals The converter can compensate up to 0 75V of voltage drop through remote sense terminals To ensure accurate regulati...

Страница 5: ...1 2 3 jumper 2 3 Unit ON jumper 1 2 ON by Remote Pin Output Voltage Adjustment jumper P1 CON1 F1 2 3 Figure 5 Accessible Adjustments A Output voltage is trimmed by adjusting the potentiometer P1 B Rem...

Страница 6: ...pair Warranty 700HS Series models come with a 2 year factory warranty covering parts and labor per the following We warrant each instrument sold by us or our authorized agents to be free from defects...

Страница 7: ...Page 5...

Страница 8: ...Page 6...

Страница 9: ...Page 7...

Страница 10: ...SEC SEC America LLC P O Box 2266 South Burlington 78 Ethan Allen Drive VT 05403 www secamerica com Tel 802 865 8388 Fax 802 865 8389 cage code 07KU1...

Отзывы: