1. Packing List

Name

Standalone Proximity Reader

Infrared remote control

Manager card

Short Pin

User manual

Self Tapping Screws

Specification 

W2

One for add, one for delete

Used for factory default setting

W2

3.5*27mm

The W2 is fully waterproof standalone Proximity access Reader, which uses advanced 
microprocessor, equipped with large capacity Flash memory, supports up to 10,000 
cards. It is so easy to add or delete card users by using the master card, besides, with 
Infrared remote control programmer, the user can set the features by themselves, 
including Alarm, Self-protection, interlock and Anti-submarine back Function. In 
additional, with infrared remote control programmer, you can add or delete cards 
directly by inputting card number.
The W2 not  only has the features of low power consumption,

 

automatic selection of lock 

,anti vandal alarm and exit button, but also has the protective functions against input over 
voltage and outputs short-circuit. These features make the W2 safe , reliable and easy in 
operation.  It  is  an ideal choice  for door access.

2. Description

Standalone Card Reader
User capacity: 10,000 
Card interface: 125KHZ EM card
Remote control for programming
With Manager cards for fast add 

    and delete users

Wiegand26 input/output

3. Features

Can be used as salve reader
2 pcsW2 can be interconnected/ interlocked
Can be used as controller by connecting 

    slave reader

Anti-submarine back Function
Alarm signal output, Door open detection
Full of 10,000 users, recognizing speed <15ms.

 

4. Specifications 

-20

60

20%

98%

Max20A

Max20A

Two

103 x 48 x 23mm

Temperature

Humidity

Lock output load 

Alarm output load 

Manager card

Dimensions

Supply Voltage

Sleeping Current

Card type

Card Reading Distance

Wiegand interface

User capacity

DC12V

10%

<15mA

125KHZ EM card

5

10cm

Wiegand 26

10,000

Drill holes on the wall or prepare the cassette.

Wire through the hole, and blanket the unused cable in case of short circuit.

Fix the back cover firmly on the cassette or the wall.

Attach the reader to the back cover.

5.  Installation

Shielded 
cables

C

D

6

1

m

m

9

5

.5

m

m

40mm

A

B

6. Wiring

No

1

2

3

4

5

6

7

8

9

10 

Color

  Yellow          

  Blue            

  Brown 

  Purple          

  Grey            

   Red          

  Black        

  White   

Green   

  Orange 

Function

   D0    

   D1   

  ALARM+ 

  OPEN 

  D_IN 

  12V

  GND 

  VSS 

L- 

L+/Alarm+  

Description

Wiegand output, input signal wire D0 

Wiegand output, input signal wire D1

connecting to the negative pole of the alarm equipment 

To connect to one part of Exit Button

Door Contact input

(+) 12Vdc Positive Regulated Power Input

(-) Negative Regulated Power Input 

the negative pole of the controller, connect to the other 

 part of Exit button and door contact

Connect to the negative pole of the Lock

Connect to the positive pole of the lock and alarm equipment

Connection Diagram

DC12V/3A

+

-

-

+

Lock

-

+

Exit button

Alarm

door detecting switch 

Common Power Supply

W 2

D0

D1

ALARM-

OPEN

D_IN

+12V

GND

VSS

L-

L+  

ALARM+

J1

Green

White

Grey

Yellow

Brown

Red

Black

Blue

Purple

Orange

DC12V/3A

+ -

COM

NC

NO

PUSH

Exit button

Alarm

door detecting switch 

F

a

il-

s

e

c

u

re

lo

c

k

F

a

il

-s

a

fe

 lo

c

k

Special Power Supply

D0

ALARM-

J1

D1

Green

White

Grey

OPEN

D_IN

+12V

GND

VSS

L+  

ALARM+

L-

Yellow

Brown

Red

Black

Blue

Purple

Orange

To add a card user(Method 2)

To delete a card user 

2    Read Card   #  or

2    Card number  (8 digit)    # 

To delete ALL users.

(

Note:

 

This option will delete all users but 

Manager Cards. Be careful with use)

2    0000    # 

1   Input Card number  (8 digit)    # 

The card number is the last 8 digits of the 
number printing on the card.

Door open detection

Door Open Too Long (DOTL) warning. When used with an optional magnetic
contact or built-in magnetic contact of the lock, if the door is opened normally, but
not closed after 1 minute, the inside buzzer will beep automatically to remind
people to close the door and continue for 1 minute before switching off
automatically.
Door Forced Open warning. When used with an optional magnetic contact or built in 
magnetic contact of the lock, if the door is forced open, or if the door is opened after 
120 seconds of the electro-mechanical lock not closed properly, the inside buzzer 
and alarm output will both operate. 

To disable door open detection.
(Factory default)

Security Mode Setting

Reader Lockout & Alarm Output options. 

If there are 10 invalid cards within 1 0 mi nut es, 

the Reader will lockout for 10 minutes or the alarm will operate for 10 minutes, 
depending on the option selected below.

Normal status (No lockout or alarm) 

7   0    #  (Factory default setting)

Anti-submarine Disabled

Anti-submarine Master Mode

Antisubmarine Auxiliary Mode

(

Note:

 the detailed wiring diagram and illustration, please refer to the 

Advanced application

) .

 (Factory default)

3   0   #

3   1   #

3   2   #

To enable door open detection

6    0    #  

6    1    #  

Reader Lockout

7   1    # 

Alarm Output

7   2    # 

Door Interlock.

Door interlock disabled

Door interlock enabled

8   0    # 

8   1    # 

Alarm output time

To set the alarm output time (0-3
minutes) Factory default is 1 minute

9   0~3    # 

I/O

ALARM-

R8

R20

Q6

Lock Interface Principle:

By programme setting, I/O 
switch between low level and 
high level.

4-low level
5-high level

I/O

L-

L+

+12V

R7

R19

Q2

D6

Alarm Interface Principle:

when alarm, the I/O outputs high level.

7. Interface Circuits

 Figure 1

8. To Reset to Factory Default and Manager Card setting

Power off, use the supplied Contact Pin to short out the 2P socket on the mainboard, 
then power on, if successful, the beeper will beep twice, the LED shines in orange, 
remove the Short Pin, then read any two EM cards, after that the LED turns in red, 
means reset to factory default setting successfully. of the two EM cards read, the first 
one is Manager add card, the second one is Manager delete card.

Remarks: Reset to factory default setting, the users' information enrolled is still retained. 
When reset to Factory default setting, the two Manager cards must be re-enrolled.

9. Sound and Light indication

Operation status 

Reset to factory default setting

Sleeping mode 

Operation successful

Enter into programming mode

Enter into setting 

Exist from programming mode

Operation failed 

Open the door

Alarm

LED

Orange

Red shines slow

Red shines

Orange shines

Red shines slow

Green shines

Red shines fast

Buzzer

Two short ring

Short ring

Short ring

Short ring

Short ring

Three short ring

Short ring

Alarm

10. W2 Detailed Programming Guide

 10.1 User settings

There are 2 ways to add and delete users:

A - By manager card;     B - By remote control 

A - By Manager card(The most convenient way)

To Delete User by Manager Card

B- By Remote control

Manager add card    Read user card   Manager  

add  card  Cards can be added continuously.

Manager delete card  Read user  card    Manager 

Delete ca rd   Cards can be deleted continuously.

To Add user by Manager Card

To add a card user (Method 1)          

1    Read Card   #  
Card can be added continuously without 
exiting programming mode.                              

To Enter the programming mode

Remarks:

 All the steps below must be done after entering into programming mode

To change the master code

 0   New Password #   Repeat New Password #

The master code must be 6 8 digit number.

*   Manager Password   #                 

888888 is the default factory master code

10.2  Door setting

Fail secure (Unlocked when power on) 

Fail safe (unlocked when power is off)

4   0

99   #

0-99 is to set the door relay time 0-99 seconds.

5    0 99     #
0-99 is to set the door relay time 0-99 seconds.

Lock Power Setting

Anti

-

submarine Settings

This is the factory default, 3 seconds:

To Unlock the door

To remove the alarm

To remove the door forced open warning

Read valid card or Master Code #

To remove the door open too long 
warning

Close the door or Read valid card 

or Master Code #

Read user card  

Note:

that Manager Card can't be used  to unlock the door. 

To Unlock the door

Please ensure that all the above contents are correct. If any are missing, please notify the supplier of the W2. 

Do not power on until all wiring has been completed

Note:

The above diagrams show the output interface circuits. Unlike most lock and 

alarm outputs which use a relay that can be shocked or magnetized, the W2 uses MOS 
outputs for both the Lock Output on the left and the Alarm Output on the right.

.2.

.3.

.4.

.5.

.1.

.6.

Отзывы: