3.10.2 Change password by ID number
* (ID number) # (old code) # (new code) # (new code) #
Example Change user’s password by ID, *1#123456#111111#111111#
Note: when changing password by ID number,the old user password can not be initial password
1234
3.11 User to open the door
Read the card or enter 6 digits user’s passwords, or press the Exit button
Note:No pressing # key after entering the password reduces frequency of using # key and greatly
improves the service life of # key. When opening the door, there will be a long sound of "beep"
and the indicator light will turn green during unlock. when the opening mode is card+code, the
interval between reading card and enter the password cannot exceed more than 5 seconds.
3.12 Resetting To Factory Default Setting
When master code is forgetted,or afer user randomly adjust various parameters, you can return to
the normal situation by resetting to factory default setting. As following:
power off,press *and hold it,then power on, release it until hear two beeps, and master code will
revert to 888888,
And the machine parameters are resetted to factory default setting,detail is in the “Programming
mode operation summary table”, the user’s card and password won’t be deleted.