6
12V
Red
(+) 12Vdc Positive Regulated Power Input
7
GND Black
(-) Negative Regulated Power Input
8
VSS Blue
the negative pole of the controller, connect to the other part of Exit
button and door contact
9 L- Purple Connect to the negative pole of the Lock
10 L+/Alarm+ Orange
Connect to the positive pole of the lock and alarm equipment
Note: Do not power on until all wiring has been completed.
3.2 Intramural interface circuit
3.3 Method of Reset to Factory default setting and re-register Manager cards
Power off, press the RESET key (SW14) on the PCB, hold it and power on, release it until hear
two short beeps, the LED shines in orange, then read any two EM cards, after that the LED turns
in red, means reset to factory default setting successfully. Of the two EM cards read, the first one
is Manager add card, the second one is Manager delete card.
Remarks: Reset to factory default setting, the users’ information enrolled is still retained. When
reset to Factory setting, the two Manager cards must be re-enrolled.
3.4 Connection diagram