8
OPERATING INSTRUCTIONS
Starting The Machine - Figures 3, 4 & 5
Before turning on your vacuum cleaner, make sure that the vacuum is in its
upright locked position and that you have a firm hold on the handle grip to keep
the machine from moving forward.
1. With the power switch (3) in the OFF position, turn the cable hook (17) to the
left or right to release the cable (4). Lift the cable off the upper cable hook -
see figure 3.
2. Adjust the telescopic handle tube (5) to the correct height by pulling out the
handle release lever (32) and gently pulling the tube out to lengthen, or push-
ing it in to shorten. The tube will click into place when it reaches one of the
three lengths available. Release the tab. If the tab does not fit snugly in place,
the tube is set at an incorrect setting. Pull or push the tube until it locks into
one of the three settings - see figure 4.
3. Plug the polarized power cord into a 120 volt wall outlet located near the floor.
4. Slide the On/OFF switch (3) downward toward the MAX position - see figure 5.
Operating the Machine - Figures 5 & 6
You may adjust the suction control with the suction control slider (3) as you vacuum different sur-
faces or when using the accessory tools. Slide the button upward for less suction or downward for
more suction - see figure 5
When changing power heads and floor tools, always switch the vacuum off with the main power
switch (3), and then unplug the power cord.
NOTE:
When switching off the power switch, always
make sure the switch “clicks” into the OFF position before unplugging the power cord.
When you have finished using the vacuum, turn it off by sliding the on/off switch to the OFF posi-
tion. Then, unplug the cord and wind it onto the upper cable hook and upper hook. The rubber tip
on the end of the handle allows the vacuum to be propped against a wall without damage.
WARNING!
The quality, condition, coating, texture, age and manufacturing technique of all floor surfaces vary.
Therefore, vacuums with rotating brushes, including your SEBO, may damage some floor coverings or surfaces. Some types
of high-gloss hardwood floors, cushion vinyl, berber carpets, long shag, and delicate or hand-woven carpets are particularly vul-
nerable to damage by rotating brushes. When possible, consult the materials supplied by your flooring manufacturer for infor-
mation on proper upkeep and cleaning.
To ensure that your new SEBO vacuum cleaner is compatible with your floor, please
!
4
Figure 3
Figure 4
17
Figure 5
+
MAX
OFF
5
Using the Hose Handle, Hose & Attachments - Figures 6 & 7
The hose handle (19) is useful for vacuuming corners and hard-to-reach areas. You may use the hose
handle with or without an attachment. Pull the hose handle (19) from the suction opening (18) in the
side of the vacuum. Keep a firm hold on the handle grip while using the hose handle as it could tip
if the hose is pulled too far. The standard attachments [the crevice nozzle (22) and upholstery noz-
zle (23)] and optional attachments [the hand-held Turbo brush (24), dusting brush (25), straight tube
(26) and extension hose (27)] may be inserted onto the hose handle. It is not necessary to turn off the
vacuum while switching the attachments.
NOTE:
When using the hose and attachments, keep the
vacuum in its upright position.
To change a floor tool or power head, switch off the power and unplug the vacuum. Press the tool
release button (14) and pull the vacuum out of the swivel neck (20). Insert the vacuum into the new
tool and push down gently until it snaps into place. Plug the vacuum in and switch the power on.
Detachable Suction Unit - Figure 7
When detached from the power head, or floor tool, the FELIX transforms itself into a lightweight,
powerful suction unit, which can be carried around using its comfortable carrying handle (figure 7).
Ideal for cleaning stairs, car interiors or upholstery. To remove a floor tool or power head, switch off the power and unplug
the vacuum. Press the tool release button (14) and pull the vacuum out of the swivel neck (20).
Full Bag or Clog Indicator – Figure 4
When a full bag, a clog in the airflow pathway, or an excessively dirty microfilter is detected, an indicator gauge on the bag
housing lid (7) “fills” with orange color. The user should turn the switch off, unplug the machine and immediately insert a new
bag or remove the clog (to remove a clog, refer to the Clog Removal section on page 12). If the airflow is still restricted, the
“BAG FULL OR CLOG” indicator will again display and the machine will shut off.
Figure 7
3
32
Figure 6
19
18
test the vacuum cleaner on each type of flooring surface in a small inconspicuous area to determine if any damage
occurs. If damage occurs, stop using the vacuum cleaner immediately!
7