Seav RES 2175 Скачать руководство пользователя страница 3

Supramatic S &

GTS

T.2

Start Contact

T.3

Start Contact

T.3

24 Volt +

T.1

24 Volt +

3 Terminals

T.1

0 Volt (Common)

T.4

0 Volt (Common)

HORMANN

T.20

0 Volt (Common)

T.2

0 Volt (Common)

Supramatic E & Promatic

T.21

Start Contact

T.3

Start Contact

GARADOR

T.5

24 Volt +

T.1

24 Volt +

Auto Expert

& M2

T.20

0 Volt (Common)

T.4

0 Volt (Common)

HORMANN

T.1

0 Volt (Common)

T.2

0 Volt (Common)

Ecostar

T.1

0 Volt (Common)

T.4

0 Volt (Common)

T.2

Start Contact

T.3

Start Contact

T.3

24 Volt +

T.1

24 Volt +

BOSCH

T.3 - PCB

24 Volt + 

T.1

24 Volt +

Profilift

T.4 - PCB

0 Volt (Common) 

T.2

0 Volt (Common)

T.5 outside

Start Contact

T.3

Start Contact

T.6 outside

0 Volt Common

T.4

Common

T.3 and T.4 are where the black wires coming from the transformer to the PCB – 17 Volt A/C

SEIP

T. G

24 Volt + 

T.1

24 Volt +

TS 75 and TS 100

T. H 

0 Volt (Common) 

T.2

0 Volt (Common)

T. A

Start Contact

T.3

Start Contact

T. B

0 Volt Common

T.4

Common

STANLEY

Left hand T. 1

24 Volt + 

T.1

24 Volt +

3 terminals on back

Right hand T. 3

0 Volt (Common) 

T.2

0 Volt (Common)

Centre T. 2

Start Contact

T.3

Start Contact

Right hand T. 3

0 Volt Common

T.4

Common

It would usually be recommended to remove any existing hard wired radio receivers before installing the new 
Seav Radio Receiver

- ALWAYS ENSURE THE 24 Volt TERMINAL IS IDENTIFIED AND CONNECTED FIRST 

– ENSURE ALL POWER IS ISOLATED AND TURNED OFF

 

Standard wiring instructions to suit most 3 terminal garage door operators not listed above:
Terminal 1, on electric operator – connect to Terminals 2 and 4 on the Seav Receiver
Terminal 2, on electric operator – connect to Terminal 3 on the Seav Receiver
Terminal 3, on electric operator – connect to Terminal 1 on the Seav Receiver

Alternative wiring instructions to suit some other garage door operators:
Terminal 1, on electric operator – connect to Terminal 1 on the Seav Receiver
Terminal 2, on electric operator – connect to Terminal 3 on the Seav Receiver
Terminal 3, on electric operator – connect to Terminals 2 and 4 on the Seav Receiver

DISCLAIMER: Every care has been taken to make sure the information contained within these wiring instructions is 
accurate. However we cannot be held liable for any subsequent damage or failure following installation 

Registered in England No 233 5784                         V A T No 527 3897 10