5
Rev. 1.3 12/04
Lamp off indicates no automatic operation, lamp on indicates
that automatic operation is activated, a slow flash shows that
the gate is opening and a rapid flash shows that the gate is
closing.
Electronic Clutch
The control board is fitted with an electronic clutch which may
be regulated using the Trimmer VR 1. The Trimmer VR1
should be regulated to permit the normal movement of the
mechanism but the mechanism should stop if an obstacle is
encountered (it is possible to test the setting, stopping the
movement by hand.)
Flashing Light
The control board allows for the connection of a 230V~
flashing light. The light’s operation is controlled by the motor/s
activity, if the pre-flash function is activated or not and if
automatic closing is activated or not activates the lamp during
the delay period.
Pressure maintenance on hydraulic engines
The central is provided from the manufacturer with the function
of pressure maintenance on disconnected hydraulic engines.
To enable the function proceed as follows: keep MODE key
pressed for 5 seconds, when it shows the simultaneous
lighting of all the
RED
Led and soon after the extinction, the
programming is completed.
To disconnect the function, repeat the above-mentioned
operation or execute the RESET procedure (all the data
memorized will be lost).
TIMER functioning :
The centre allows a timer to be connected instead if the open-
close (PUL) button command.
For example: the timer can be set to open the gates at 8am
and to close at 6pm. During this period automatic closing and
flashing signals are disactivated.
P
ROGRAMMING
SEL Button
: selects the type of function to be memorised. The
selection is indicated by a flashing Led.
By repeatedly pressing the button it is possible to choose the
desired function. The selection will remain active for 10
seconds, indicated by a flashing Led, if no other operations
are executed during this period the control board will return to
its previous state.
MODE Button:
Programmes the information relative to the type
of function previously selected with the SEL button.
LED Ref.
LED OFF
LED ON
1) 1-2 MOTORI
1 motor automated
2 motors
automated
2) CODE
No Code
Code activated
3) CODE PED.
No code
Code activated
4) INB.CMD:AP
OFF
ON
5) PED/ANTA S.
Pedestrian
Single gate
6) COLPO ARIETE
OFF
ON
7) PRELAMP.
OFF
ON
8) T. MOT.
4 minute activity
Programmed delay
9) T.PAUSA
No automatic close Automatic close
10) RIT.ANTE AP
No gate delay
Programmed delay
11) RIT.ANTE AP
No gate delay
Programmed delay
12) POWER
Mains ON
Mains OFF
1) 1-2 MOTORS
The control board is supplied with the possibility to choose
between two pre-set configurations for mechanisms with 1-2
motors. The factory set-up and pre-set default is for typical
operation with one motor only (for example a rolling gate). If
the mechanism is required to operate two motors
simultaneously (for example a double gate) follow these
instructions: using the SEL button, select the 1-2 Motori led
(flashing), pressing the MODE button will cause the 1-2
MOTORI led to remain on.
To deactivate this function (i.e. return to default, one motor
operation) follow these instructions: using the SEL button,
select the 1-2 Motori led (flashing), pressing the MODE button
will cause the 1 -2 MOTORI led to remain off.
2) CODE
:
Radio control code
The board allows the memorisation up to 120 radio
commands having different codes, which are either fixed or
rolling code.
Programming.
The transmission code is programmed in the following
manner: press the SEL button until the CODE led flashes,
immediately transmit the pre-selected code with the desired
remote control, in the m oment in which the led CODE remains
accessible, the programming, will be complete
When all 120
codes have been stored in the memory all the Led lights will
flash, signalling that nothing else can be stored..
Programming through Radio command.
This procedure, consents to enable the programming, without
direct intervention of the SEL task on the panel, but executing
the operation at a distance, allows the programming of
transmission codes without the having to use the SEL button
on the central direct. The ability of programming is executed in
the following manner: send in a continuous manner for max.
10 seconds the codes of the radio command previously
memorised, at the same time the panel will enter into
programming mode as explained above.
Ability of programming through Radio command.
The panel is furnished by the builder with the radio command
disabled, if you wish to enable the function, proceed in the
following manner: the panel board is powered by an output of
230VAC, keeping the SELL task pressed, at the same time
you will obtain a brief flashing of all the Leeds and the
programming will be complete.
If you wish to disable the function previously enabled, repeat
the operation or follow the RESET procedure.
Cancellation.
All the transmission codes are cancelled in the following
manner: press the SEL button until the CODE led flashes,
then press the MODE button and the CODE Led will be turned
off and the cancellation will be completed.
3) CODE PED
:
Ped./Anta S. radio control code
The programming procedure is the same as above except that
the led selected should be CODE PED.
4) INB. CMD. AP
:
Suppression of commands during opening
The control board is supplied with the suppression of
commands during opening deactivated (INB. CMD. AP. Led
off). To activate this function, follow these instructions: press
the SEL button until the INB. CMD. AP. Led flashes then press
the MODE button and the INB. CMD. AP. Led will remain lit. To
deactivate this function, follow these instructions: press the
Содержание LRX 2100
Страница 4: ...7 Rev 1 3 12 04 ...