Rev. 1.3  12/04 

Lamp off indicates no automatic operation, lamp on indicates 
that automatic operation is activated, a slow flash shows that 
the gate is opening and a rapid flash shows that the gate is 
closing. 

Electronic Clutch 

The control board is fitted with an electronic clutch which may 
be regulated using the Trimmer VR 1. The Trimmer VR1 
should be regulated to permit the normal movement of the 
mechanism but the mechanism should stop if an obstacle is 
encountered (it is possible to test the setting, stopping the 
movement by hand.) 

Flashing Light 

The control board allows for the connection of a 230V~ 
flashing light. The light’s operation is controlled by the motor/s 
activity, if the pre-flash function is activated or not and if 
automatic closing is activated or not activates the lamp during 
the delay period. 

Pressure maintenance on hydraulic engines

 

The central is provided from the manufacturer with the function 
of pressure maintenance on disconnected hydraulic engines. 
To enable the function proceed as follows: keep MODE key 
pressed for 5 seconds, when it shows the simultaneous 
lighting of all the 

RED

 Led and soon after the extinction, the 

programming is completed. 
To disconnect the function, repeat the above-mentioned 
operation or execute the RESET procedure (all the data 
memorized will be lost). 

 
TIMER functioning : 

The centre allows a timer to be connected instead if the open-
close (PUL) button command. 
For example: the timer can be set to open the gates at 8am 
and to close at 6pm. During this period automatic closing and 
flashing signals are disactivated.  

P

ROGRAMMING

 

SEL Button

: selects the type of function to be memorised. The 

selection is indicated by a flashing Led. 
By repeatedly pressing the button it is possible to choose the 
desired function. The selection will remain active for 10 
seconds, indicated by a flashing Led, if no other operations 
are executed during this period the control board will return to 
its previous state. 

MODE Button:

 Programmes the information relative to the type 

of function previously selected with the SEL button. 

LED Ref. 

LED OFF 

LED ON 

1) 1-2 MOTORI 

1 motor automated 

2 motors 
automated 

2) CODE 

No Code 

Code activated 

3) CODE PED. 

No code 

Code activated 

4) INB.CMD:AP 

OFF 

ON 

5) PED/ANTA S. 

Pedestrian 

Single gate  

6) COLPO ARIETE 

OFF 

ON 

7) PRELAMP. 

OFF 

ON 

8) T. MOT. 

4 minute activity 

Programmed delay 

9) T.PAUSA 

No automatic close  Automatic close 

10) RIT.ANTE AP 

No gate delay 

Programmed delay 

11) RIT.ANTE AP 

No gate delay 

Programmed delay 

12) POWER 

Mains ON 

Mains OFF 

1) 1-2 MOTORS 

The control board is supplied with the possibility to choose 
between two pre-set configurations for mechanisms with 1-2 
motors. The factory set-up and pre-set default is for typical 
operation with one motor only (for example a rolling gate). If 
the mechanism is required to operate two motors 
simultaneously (for  example a double gate) follow these 
instructions: using the SEL button, select the 1-2 Motori led 
(flashing), pressing the MODE button will cause the 1-2 
MOTORI led to remain on. 
To deactivate this function (i.e. return to default, one motor 
operation) follow these instructions: using the SEL button, 
select the 1-2 Motori led (flashing), pressing the MODE button 
will cause the 1 -2 MOTORI led to remain off. 

2) CODE

:

 

Radio control code

 

The board allows the memorisation up to 120 radio 
commands having different codes, which are either fixed or 
rolling code. 

Programming. 

The transmission code is programmed in the following 
manner: press the SEL button until the CODE led flashes, 
immediately transmit the pre-selected code with the desired 
remote control, in the m oment in which the led CODE remains 
accessible, the programming, will be complete

 When all 120 

codes have been stored in the memory all the Led lights will 
flash, signalling that nothing else can be stored..

 

Programming through Radio command. 

This procedure, consents to enable the programming, without 
direct intervention of the SEL task on the panel, but executing 
the operation at a distance, allows the programming of 
transmission codes without the having to use the SEL button 
on the central direct. The ability of programming is executed in 
the following manner: send in a continuous manner for max. 
10 seconds the codes of the radio command previously 
memorised, at the same time the panel will enter into 
programming mode as explained above.   

Ability of programming through Radio command. 

The panel is furnished by the builder with the radio command 
disabled, if you wish to enable the function, proceed in the 
following manner: the panel board is powered by an output of 
230VAC, keeping the SELL task pressed, at the same time 
you will obtain a brief flashing of all the Leeds and the 
programming will be complete.  

If you wish to disable the function previously enabled, repeat 
the operation or follow the RESET procedure.  

Cancellation.

  

All the transmission codes are cancelled in the following 
manner: press the SEL button until the CODE led flashes, 
then press the MODE button and the CODE Led will be turned 
off and the cancellation will be completed. 

3) CODE PED

:

 

Ped./Anta S. radio control code

 

The programming procedure is the same as above except that 
the led selected should be CODE PED. 

4) INB. CMD. AP

:

 Suppression of commands during opening

 

The control board is supplied with the suppression of 
commands during opening deactivated (INB. CMD. AP. Led 
off). To activate this function, follow these instructions: press 
the SEL button until the INB. CMD. AP. Led flashes then press 
the MODE button and the INB. CMD. AP. Led will remain lit. To 
deactivate this function, follow these instructions: press the 

Отзывы: