background image

unit  disables  the  flashing  beacon,  the  automatic  closing  stage 
and the radio controls.

 

 
PROGRAMMING:
 
 
SEL button: selects the type of function to be stored; selection 
is indicated by a flashing LED.

 

The  desired  function  can  be  selected  by  pressing  the  button 
repeatedly.    The  selection  remains  active  for  10  seconds 
(indicated  by  the  flashing  LED);  after  10  seconds,  the  control 
unit returns to its original status.

 

SET button: programmes the information according to the type 
of function selected previously using the SEL button.

 

IMPORTANT:  The  function  of  the  SET  button  can  be  replaced 
with  the  radio  control,  if  programmed  previously  (CODE  LED 
on).

 

 

MAIN MENU 

The  control  unit  is  supplied  by  the  manufacturer  with  the 
possibility of selecting some important functions. 

 

---------------------- MAIN MENU -----------------

 

Reference LED                  LED Off                                 LED On

 

1) CODE                            No code                           Code entered

 

2) INB.CMD.AP                  Disabled                          Enabled

 

3) LAMP/CORT                  Flashing                          Courtesy light

 

4)  T.  MOT.                                Automatic  motor  time                                Time 
programmed

 

5)  T.  PAUSA.                        Without  aut.  closing                                    With  aut. 
closing

 

6) SEL DS1                   CH = INV.                             AP/CH = BL

 

7) SEL DS2                   CH = INV.                             AP/CH = 
BL+INV.

 

8) SEL DS3                   CH = INV.                             AP/CH = BL

 

 
1) CODE: 
 (Radio control code)

 

The control unit can store up to 75 radio controls with different 
fixed or rolling codes. 
 
Programming using a 1- or 2-button radio control: 
To  programme  the  transmission  codes  in  the  radio  control, 
proceed  as  follows:  press  the  SEL  button  and  the  CODE  LED 
will  begin  to  flash;  at  the  same  time  send  the  first  code  ("Up", 
corresponding  to  the  opening  movement)  on  the  radio  control. 
At this point the CODE LED will begin to flash quickly. Send the 
second code (“Down”, corresponding to the closing movement) 
to be stored and the CODE LED will remain lit: programming is 
now complete. If the second code is not sent within 10 seconds 
the  control  unit  exits  the  programming  stage,  selecting  the 
function using a single button on the radio control. 

 

 
Programming using a 3 button radio control in the “BeFree 
Series”: 
The  control  unit  allows  you  to  store  the  whole  “BeFree”  radio-
control by programming only the UP button. 

 

To  programme  the  “BeFree”  radio-control  codes,  follow  this 
procedure:  press  the  SEL  button;  the  CODE  LED  begins  to 
flash.  Press  the  UP  button  of  the  desired  radio  control  at  the 
same time; the CODE LED will remain lit and programming will 
be complete. 

 

Deleting the codes: 

To  delete  all  transmission  codes 

stored  in  the  memory,  proceed  as  follows:  press  the  SEL 
button;  the  CODE  LED  starts  flashing.  Then  press  the  SET 
button;  the  CODE  LED  switches  off  and  the  procedure  is 
complete.

 

Maximum  number  of  radio  controls  which  can  be  stored
The control unit can store up to 75 radio controls with different 
fixed or rolling codes. If the maximum number of radio controls 
has  been  reached,  and  a  programming  process  started,  the 
control  unit  will  indicate  that  the  programming  process  has 
failed by flashing all the LEDs except the CODE LED, which will 
remain  lit  in  a  constant  manner.  After  10  seconds  the  control 
unit exits the programming mode.

 

2)  INB.  CMD.  AP:  (command  inhibition  during  opening  and 
pause time, if entered)

 

The  command  inhibition  function  during  opening  and  pause 
time,  if  entered,  is  used  when  automation  includes  the  loop 
detector. During opening or pause time the control unit ignores 
the  commands  given  by  the  loop  detector,  push-button  station 
and radio control. During the closing phase a command sent by 
the  loop  detector,  push-button  station  or  1-button  radio control 
will cause the motor direction to be inverted; if operating with a 
2-button  radio  control  the  button  corresponding  to  opening  will 
cause  the  motor  direction  to  invert  and  the  closing  button  is 
ignored;  if  operating  with  a  radio  control  in  the  BeFree  series 
the  opening  button  causes  inversion,  the  closing  button  is 
ignored and the Stop button causes the motor to stop. 

 

The  control  unit  is  supplied  with  the  default  setting  of  the 
command inhibition function during opening and pause time not 
enabled.  To  enable  the  function  proceed  as  follows:  use  the 
SEL button to navigate to INB.CMD.AP when the relevant LED 
is  flashing,  then  press  the  SET  button:  the  INB.CMD.AP  LED 
lights up and remains constant. Repeat the operation to restore 
the previous configuration.

 

 
3)  LAMP/CORT:  
(Selection  of  flashing  beacon  or  courtesy 
light)

 

The  control  unit  has  an  output  of  230  V  a/c  500  W  for 
connection to a flashing beacon or courtesy light. 
The  control  unit  is  supplied  by  the  manufacturer  with  the 
flashing  beacon  function  enabled  (even  when  the  unit  is 
paused).  To  enable  the  flashing  beacon  function  proceed  as 
follows:  use  the  SEL  button  to  navigate  to LAMP/CORT. when 
the  corresponding  LED  is flashing, then press the SET button: 
the LAMP/CORT. LED lights up and remains constant. 

 

Repeat the operation to restore the default configuration. 
To  enable  the  courtesy  light,  repeat  the  operation  above,  by 
pressing  the  SEL  button  twice  (LAMP/CORT  LED  flashes 
rapidly)  instead  of  once.

 

Repeat  the  operation  to  restore  the 

default configuration.

 

Flashing beacon function while the unit is paused: 
The 230 V a/c output will activate every time automation takes 
place,  for the duration of the motor timer. If the Pause Time is 
stored,  the  230  V  a/c  output  will  also  be  active  during  the 
Pause.

 

Flashing Beacon Operation: 

The  230  V  a/c  output  will 

activate  every  time  automation  takes  place,  for  the  duration  of 
the motor timer. 

 

Courtesy  Light  Operation:  The  230  V  a/c  output  will  activate 
for 3 minutes every time an opening command is given. 

 

 
4) T. MOT:
 

(Motor operation time of max. 4 minutes)

 

The  control  unit  is  supplied  by  the  manufacturer  with  the 
Automatic  Motor  Timer  enabled,  this  way  the  control  unit 
removes the power supply from the motor 1 second after it has 
reached the motor's internal stop limit. If there is an established 
motor  operation  time  and  an  Automatic  Motor  Timer  which  is 
disabled,  proceed  as  follows  when  the  shutter  is  closed  to 
perform the programming process: use the SEL button to reach 
the stage where the T. MOT LED flashes, then press press the 
SET  button  briefly;  the  Motor  will  begin  the  Opening  cycle. 
When  the  shutter  reaches  the  desired  position  press  the  SET 
button. The motor time is stored and the T. MOT. LED remains 
lit in a constant manner. 
To  restore  the  initial  configuration  (with  the  Automatic  Motor 
Timer  function  enabled)  navigate  to  the  stage  where  the  T. 
MOT. LED is flashing then press the SET button twice within 2 
seconds; the LED switches off and the operation is complete. 
During programming the radio control button on the control unit 
can be used instead of the SET button, if stored previously. 
 
5) T. PAUSA:
 

(Programming aut. closing time of max. 4 min.)

 

The  control  unit  is  supplied  by  the  manufacturer  without  an 
automatic  closing  procedure.  To  enable  the  automatic  closing 
function  proceed  as  follows:  use  the  SEL  button  to  reach  the 
stage where the T. PAUSA LED is flashing, then press the SET 
button,  wait  for  the  desired  pause  time,  then  press  the  SET 

Содержание LRS 2197

Страница 1: ...and the button will need to be pressed again to reactivate the motor in the opposite direction Operation using a 2 button radio control The following type of operation is obtained using a radio control with 2 buttons the first button Up corresponding to the opening movement controls opening until the motor stops running and the second button Down corresponding to the closing movement controls the ...

Страница 2: ...tector push button station or 1 button radio control will cause the motor direction to be inverted if operating with a 2 button radio control the button corresponding to opening will cause the motor direction to invert and the closing button is ignored if operating with a radio control in the BeFree series the opening button causes inversion the closing button is ignored and the Stop button causes...

Страница 3: ...utton To programme the transmission code remotely proceed as follows send the radio control code continuously for more than 10 seconds the control unit will enter the programming mode as described above for the CODE LED in the main menu The control unit is supplied by the manufacturer with remote programming of the transmission code not enabled to enable the function proceed as follows check that ...

Страница 4: ...ugh the simultaneous flashing of all LEDs except the T MOT LED which will remain lit in a constant manner We recommend a qualified technician is contacted immediately in order to resolve the problem Once the correct operating conditions are restored the control unit may be switched on again The error status is reset and the control unit is ready to operate normally DS1 DS2 DS3 safety device test T...

Страница 5: ...g parts where an individual may become entangled so that it is impossible for anyone to be pushed or lifted by the door Do not use the control unit in conjunction with exit door sites or emergency exit routes We advise that you also take note of the following recommendations Before shutter automation it is necessary to check the product is in good condition and that it complies with EN 12604 and t...

Страница 6: ...is instruction manual in a safe place and adhere to the important safety instructions contained within it Non adherence to these instructions may lead to property damage and serious accidents Examine the system frequently to check for any signs of damage Do not use the device if it needs to be repaired Rev 2 2 dated 02 04 07 The below products Electronic Control Unit LG 2197 LRS 2197 LRS 2197 SET ...

Отзывы: