3 rev. 3.0 13/06/2016
Automatic closing :
The control unit closes the gate automatically without sending
additional commands.
The choice of this operating mode is described in the
instructions for setting the delay period.
Safety Device (Photocells):
The control unit allows for the connection and control of
Photocells, Tyre sensors (NC).
- DS Input (NC)
Commands from the Safety Device are ignored during opening,
whereas during closing they will reverse the direction of
movement.
Opening and Closing Limit Switch:
The control unit allows the Opening and Closing Limit Switch
connection (NC). When it is triggered during the respective
operating phases, movement stops immediately.
Warning: If not used this input must be jumped.
PROGRAMMING :
SEL key: selects the type of function to be stored, selection is
indicated by a flashing LED.
Repeatedly press the key to select the desired function. The
selection remains active for 10 seconds, (indicated by the
flashing LED); after 10 seconds, the control unit returns to its
original status.
The SET key: this programs the information according to the
type of function previously selected with the SEL button.
IMPORTANT: The function of the SET key can be replaced with
the radio control, if programmed previously (CODE led on).
MAIN MENU
The control unit is supplied by the manufacturer with the
possibility of selecting a number of important functions.
---------------------- MAIN MENU -----------------
Led Reference Led off Led On
1) CODE No code Code entered
2) LAMP/CORT. Flashing Courtesy Light
3) T. MOT. Motor time 30 sec. Programmed time
4) T. PAUSA No auto close With auto close
1) CODE: (Programming the Radio controls and/or
Transponder)
The control unit can store up to 120 different Radio Controls,
Transponders, Digital keyboards, Smartphones
Programming Transponders, Keyboard or Smartphone
NFC codes :
The devices are programmed as follows: press the SEL key,
the CODE LED will start flashing and at the same time move
the transponder nearer to the BeSAFE Reader New, activate
the BeSafe KeyBoard or move the Smartphone nearer to the
BeSAFE NFC Reader, the CODE LED will be lit and steady for
a moment indicating it has been stored; then the CODE LED
will continue flashing for 10 seconds while waiting for another
device to be stored, after which it will exit the programming
mode.
Programming the radio control with 1 or 2 Keys.
The radio control transmission codes are programmed as
follows: press the SEL key, the CODE LED will start flashing, at
the same time send the first radio control code ("Up"
associated to the Opening direction); now the CODE LED will
start flashing rapidly, send the second code ("Down"
associated to the Closing direction) to be stored, the CODE
LED will remain on and programming will be complete. If the
second code is not sent within 10 seconds the control unit will
exit the programming phase and select the function with only
one key of the radio control.
Programming the “BeFree Series” radio control with 3
Keys.
The control unit can store the whole “BeFree” radio control by
programming only the UP Key.
The "BeFree" radio control codes are programmed as follows:
press the SEL key, the CODE LED will start flashing, at the
same time press the UP key of the desired radio control; the
CODE LED will remain on and programming will be complete.
Deletion:
All the stored devices are deleted as
follows: press the SEL key, the CODE LED will start flashing,
then press the SET key for a few seconds, the CODE LED will
turn off and the codes are deleted.
Device already stored or not compatible warning:
The control unit can store up to 120 devices with different
codes. If the user attempts to perform the programming
procedure for a device which is already stored in the memory or
which is not compatible, the CODE LED will start flashing
rapidly for a few moments to indicate that this procedure cannot
be performed. The unit then returns to the programming phase
once again.
Maximum number of devices that can be stored:
The control unit can store up to 120 devices with different
codes. If the maximum number of devices has been reached
and a programming process started, the control unit will
indicate that it has failed by flashing all the LEDs except the
CODE LED which will remain lit and steady. After 10 seconds
the control unit exits programming mode.
2) LAMP/CORT. : (Selection of the flashing light or the
courtesy light)
The control unit has a 230 Vac output, for connection to a
flashing light or a courtesy light.
The control unit is supplied by the manufacturer with the
Flashing function enabled. If you wish to enable the flashing
beacon function, including during pauses, proceed as follows:
using the SEL key to move to the LAMP/CORT flashing LED
then press the SET key, and the LAMP/CORT flashing LED will
switch on steady.
Repeat the operation if you wish to restore the factory setting.
If you wish to enable the courtesy light, repeat the operation
described above, pressing the SEL button twice instead of
once (making the LAMP/CORT LED flash rapidly).
Repeat the
operation if you wish to restore the factory setting.
3) T. MOT: (Programming the motor operating time max. 4
minutes)
The control unit is supplied by the manufacturer with a working
time motor predefined equal to 30 sec.
If the motor operating time has to be reprogrammed, it must be
carried out when the gate is closed, as follows: use the SEL
key to move to the flashing T.MOT LED, then continuously
press the SET key. The frame will start moving up. When you
have reached the required height, release the SET key and at
the same time the motor time storage will be completed and the
T. MOT. LED will remain lit and steady. If you want an infinite
motor time, use the SEL key to navigate to the T.MOT LED
when flashing and press the SET key for less than 1 second. At
the same time the LED will turn off and the operation will be
completed. It is advisable to store a time that is a few seconds
longer after the frame has reached the end.
During programming the radio control key of the control unit
can be used instead of the SET key, if stored previously.