Automatic closing : 
The  control  unit  closes  the  gate  automatically  without  sending 
additional commands. 
The  choice  of  this  operating  mode  is  described  in  the 
instructions for setting the delay period. 

 

Safety Device (Photocells): 
The  control  unit  allows  for  the  connection  and  control  of 
Photocells, Tyre sensors (NC).  
   - DS Input (NC) 
Commands from the Safety Device are ignored during opening, 
whereas  during  closing  they  will  reverse  the  direction  of 
movement. 
 
Opening and Closing Limit Switch: 
The  control  unit  allows  the  Opening  and  Closing  Limit  Switch 
connection  (NC).  When  it  is  triggered  during  the  respective 
operating phases, movement stops immediately.  
WarningIf not used this input must be jumped. 
 
PROGRAMMING : 
 
SEL key: selects the type of function to be stored, selection is 
indicated by a flashing LED. 
Repeatedly  press  the  key  to  select  the  desired  function.    The 
selection  remains  active  for  10  seconds,  (indicated  by  the 
flashing  LED);  after  10  seconds,  the  control  unit  returns  to  its 
original status.  
The  SET  key:  this  programs  the  information  according  to  the 
type  of  function  previously  selected  with  the  SEL  button. 
IMPORTANT: The function of the SET key can be replaced with 
the radio control, if programmed previously (CODE led on). 

 

MAIN MENU 

The  control  unit  is  supplied  by  the  manufacturer  with  the 
possibility of selecting a number of important functions. 

---------------------- MAIN MENU ----------------- 

Led Reference Led off Led On 

1) CODE                     No code                          Code entered 
2) LAMP/CORT.      Flashing                           Courtesy Light  
3) T. MOT.           Motor time 30 sec.             Programmed time 
4) T. PAUSA       No auto close                       With auto close 

 
1)  CODE:  
  (Programming  the  Radio  controls  and/or 
Transponder) 
 
The  control  unit  can  store  up  to  120  different  Radio  Controls, 
Transponders, Digital keyboards, Smartphones 
 
Programming  Transponders,  Keyboard  or  Smartphone 
NFC codes : 
The  devices  are  programmed  as  follows:  press  the  SEL  key, 
the  CODE  LED  will  start  flashing  and  at  the  same  time  move 
the  transponder  nearer  to  the  BeSAFE  Reader  New,  activate 
the  BeSafe  KeyBoard  or  move  the  Smartphone  nearer  to  the 
BeSAFE NFC Reader, the CODE LED will be lit and steady for 
a  moment  indicating  it  has  been  stored;  then  the  CODE  LED 
will  continue  flashing  for  10  seconds  while  waiting  for  another 
device  to  be  stored,  after  which  it  will  exit  the  programming 
mode. 
 
Programming the radio control with 1 or 2 Keys. 
The  radio  control  transmission  codes  are  programmed  as 
follows: press the SEL key, the CODE LED will start flashing, at 
the  same  time  send  the  first  radio  control  code  ("Up" 
associated  to  the  Opening  direction);  now  the  CODE  LED  will 
start  flashing  rapidly,  send  the  second  code  ("Down" 
associated  to  the  Closing  direction)  to  be  stored,  the  CODE 
LED  will  remain  on  and  programming  will  be  complete.  If  the 
second  code  is not sent within 10 seconds the control unit will 
exit  the  programming  phase  and  select  the  function  with  only 
one key of the radio control.  

 
Programming  the  “BeFree  Series”  radio  control  with  3 
Keys. 
The  control  unit  can  store  the  whole  “BeFree”  radio  control  by 
programming only the UP Key.  
The  "BeFree"  radio  control  codes  are  programmed  as  follows: 
press  the  SEL  key,  the  CODE  LED  will  start  flashing,  at  the 
same  time  press  the  UP  key  of  the  desired  radio  control;  the 
CODE LED will remain on and programming will be complete.  
 
Deletion:
 

All  the  stored  devices  are  deleted  as 

follows:  press  the  SEL  key,  the  CODE  LED  will  start  flashing, 
then press the SET key for a few seconds, the CODE LED will 
turn off and the codes are deleted. 
 
Device already stored or not compatible warning: 
The  control  unit  can  store  up  to  120  devices  with  different 
codes.  If  the  user  attempts  to  perform  the  programming 
procedure for a device which is already stored in the memory or 
which  is  not  compatible,  the  CODE  LED  will  start  flashing 
rapidly for a few moments to indicate that this procedure cannot 
be performed. The unit then returns to the programming phase 
once again. 
 
Maximum number of devices that can be stored: 
The  control  unit  can  store  up  to  120  devices  with  different 
codes.  If  the  maximum  number  of  devices  has  been  reached 
and  a  programming  process  started,  the  control  unit  will 
indicate  that  it  has  failed  by  flashing  all  the  LEDs  except  the 
CODE  LED  which  will  remain  lit  and  steady.  After  10  seconds 
the control unit exits programming mode. 
 
2)  LAMP/CORT.  :  
(Selection  of  the  flashing  light  or  the 
courtesy light) 
The  control  unit  has  a  230  Vac  output,  for  connection  to  a 
flashing light or a courtesy light. 
The  control  unit  is  supplied  by  the  manufacturer  with  the 
Flashing  function  enabled.  If  you  wish  to  enable  the  flashing 
beacon  function,  including  during  pauses,  proceed  as  follows: 
using  the  SEL  key  to  move  to  the  LAMP/CORT  flashing  LED 
then press the SET key, and the LAMP/CORT flashing LED will 
switch on steady.  
Repeat the operation if you wish to restore the factory setting. 
If  you  wish  to  enable  the  courtesy  light,  repeat  the  operation 
described  above,  pressing  the  SEL  button  twice  instead  of 
once  (making  the  LAMP/CORT  LED  flash  rapidly).

 

Repeat  the 

operation if you wish to restore the factory setting. 
 
3)  T.  MOT:
  (Programming  the  motor  operating  time  max.  4 
minutes) 
The control unit is supplied by the manufacturer with a working 
time motor predefined equal to 30 sec. 
If the motor operating time has to be reprogrammed, it must be 
carried  out  when  the  gate  is  closed,  as  follows:  use  the  SEL 
key  to  move  to  the  flashing  T.MOT  LED,      then  continuously 
press  the  SET  key.  The  frame  will  start  moving  up.  When  you 
have  reached  the  required  height,  release  the  SET key and at 
the same time the motor time storage will be completed and the 
T.  MOT.  LED  will  remain  lit  and  steady.  If  you  want  an  infinite 
motor  time,  use  the  SEL  key  to  navigate  to  the  T.MOT  LED 
when flashing and press the SET key for less than 1 second. At 
the  same  time  the  LED  will  turn  off  and  the  operation  will  be 
completed.  It is advisable to store a time that is a few seconds 
longer after the frame has reached the end. 
During  programming  the  radio  control  key  of  the  control  unit 
can be used instead of the SET key, if  stored previously. 
 
 
 
 
 
 
 
 

Содержание LG 2060 New Reader

Страница 1: ...relevant support which is fitted to the casing in such a way as to leave said support facing downwards and insert the fixing screws in the special holes 7 The control unit does not have any type of isolating device for the 230 Vac line It is therefore the responsibility of the installer to set up an isolating device inside the system It is necessary to install an omnipolar switch surge category II...

Страница 2: ...l Keyboards Smartphones and stores up to 120 different users For use with radio controls the receiver unit is equipped with an incorporated receiver for use of the other devices the desired accessory must be connected by carefully following the connection diagrams described in the relative operating manuals supplied as optionals Operation with different radio control models Different radio control...

Страница 3: ... with 3 Keys The control unit can store the whole BeFree radio control by programming only the UP Key The BeFree radio control codes are programmed as follows press the SEL key the CODE LED will start flashing at the same time press the UP key of the desired radio control the CODE LED will remain on and programming will be complete Deletion All the stored devices are deleted as follows press the S...

Страница 4: ...her the Radio Control Transponder Digital keyboard Smartphone or the low voltage push button panel to operate the frame you will obtain the following function the first impulse commands opening until the motor time expires the second impulse commands frame closing If an impulse is sent before the motor time expires the control unit changes the direction of motion in the opening and closing phases ...

Страница 5: ...t means the input is closed when a LED is off it means the input is open MANAGING PROGRAMMING LEDS After 3 minutes of inactivity in the programming procedure the control unit will automatically switch off the programming LEDs to save energy The LEDs will light up depending on the previously set programs only when the SEL or SET keys are pressed or when a motion command has been received ...

Отзывы: