BUILT – IN ENCODING PHOTOCELLS “ IR/IT 2126 NEW “
Built-in encoding photocells, range of up to 30 mt.
The code for the transmitted signal, which must be set at the time of installation, minimises the possibility of interference
between devices.
T
ECHNICAL DATA
:
- Max. range
: 30 metres
- TX power supply
: 12-24V AC-DC
- RX power supply
: 12-24V AC-DC
- TX absorption
: 10 mA Max.
- RX absorption
: 25 mA Max.
- Relay contact capacity
: 1A max at 30 VDC
- Operating temperature
: -10
÷
55 °C
- Container
: Polycarbonate
- Protection rating
: IP 54
Selecting Operating Code “ A ” and “ B “ ( Jumper J1 ) :
The photocell has two operating encoding channels "A" and "B", in this way it is possible to install 2 pairs of the same model
without any interference between them. Code "A" ( J1 pos. 1-2 “factory configuration” ) or code “B” ( J1 pos. 2-3 ), must be
accordingly selected in the same way, at the time of installation, on both the transmitting part ( IT 2126 NEW ) and the
receiving part ( IR 2126 NEW ).
IT
2126
NEW
D
ESCRIPTION OF THE
T
RANSMITTER
(
TX
)
:
Power supply:
The Transmitter can be powered with 12 or 24 Volts in either DC (observing the polarity) or in AC
Connections:
1 – Power Supply 12-24 Vac-Vdc
2 – Power Supply 0V
IR
2126
NEW
D
ESCRIPTION OF THE
R
ECEIVER
(RX):
Power supply:
The receiver can be powered with 12 or 24 Volts in either DC (observing the polarity) or in AC.
Connections:
1 - 12-24 Vac-Vdc Power Supply
2 - 0 Vac-Vdc Power Supply
3 - NO photocell contact ( Normally Open )
4 -
NC photocell contact ( Normally Closed )
5 - C photocell contact ( Common )