1. Use the fan reverse switch, located on the switch 

housing to optimize your fan for seasonal performance.

Using a ceiling fan will allow you to raise your thermostat 

setting in summer and lower your thermostat setting in 

winter without feeling a difference in your comfort.

Note:

  Wait for the fan to stop before moving the reverse 

switch.

In warmer weather,

 push the reverse switch down which 

will result in downward airflow creating a wind chill effect.

In cooler weather,

 push the reverse switch up which will 

result in upward airflow that can help move stagnant, hot 

air off the ceiling area.

Reverse Switch

18

18. Restore power at the main fuse or circuit breaker. 

17.  

INSTALLATION WITHOUT LIGHT KIT 

(OPTIONAL)

a. Remove the three switch housing screws from the 

switch housing at the top of the light kit. 

b. Attach the switch housing cap to the switch housing 

using the three previously removed switch housing 

screws. 

Note:

 Align the notch in the switch housing cap 

with the reverse switch. 

c. Attach the pull chain extension. 

Switch 

Housing Cap

Reverse 

Switch

Plug Button

Switch 

Housing 

Screw

17

2. The fan pull chain has four positions to control the fan 

speed. One pull is HIGH, two is MEDIUM, three is LOW, 

and four turns the fan OFF. The pull chain in the center of 

the light kit turns the lights ON and OFF. 
 

2

Fan Pull Chain

Light Pull 

Chain

Содержание 269800

Страница 1: ...armateo 42 LED Ceiling Fan Owner s Manual 1 Part 269800 Exclusively Distributed By HD Supply Facilities Maintenance Ltd Atlanta GA 30339 2019 Made in China To Reorder 1 800 431 3000 hdsupplysolutions com ...

Страница 2: ...s Manual 19 Mounting Bracket Screw x4 20 Closemount Screw x3 21 Set Screw x2 22 Wire Connector x3 23 Pull Chain Extension x2 24 Blade Screw x4 25 Blade Washer x4 Unpack your fan and check the contents You should have the following items PACKAGE CONTENTS HARDWARE CONTENTS Note Some extra hardware has been included The quantity listed above is the number required for installation 22 23 24 25 Hardwar...

Страница 3: ...d is best suited for ceilings lower than 8 feet It does not utilize the downrod Downrod Mount is best suited for ceilings 8 ft or higher For taller ceilings you may want to use a longer downrod not included Angled Ceiling Mount is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance from the ceiling If using the angle mount check to en...

Страница 4: ...tial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be dete...

Страница 5: ...arked acceptable for fan support and use the mounting screws and washers provided with the outlet box 4 4 CLOSEMOUNT INSTALLATION OPTIONAL a Remove the three Phillips head closemount screws from the top of the motor assembly b Remove the canopy cover from the bottom of the canopy c Align the holes in the bottom of the canopy with the screw holes in the top of the motor housing The larger holes in ...

Страница 6: ...ded Then strip 1 2 of insulation from the end of each wire 8 Lift the downrod into the mounting bracket Rotate the downrod until the tab in the mounting bracket is seated in the slot in the downrod ball WARNING The fan and or downrod should not rotate in the mounting bracket if installed correctly Failure to align the slot in the downrod ball with the tab may result in fan falling causing serious ...

Страница 7: ... supply wire Connect the white wire from the fan to the white neutral common supply wire Connect the black and blue wires from the fan to the black live hot supply wire Note If there is a second hot power wire coming from the outlet box connect it to the blue light power fan wire for separate light and fan control Important After the connections have been made the connected wires should be turned ...

Страница 8: ...Glass Shade 16 Pull Chain Extension 16 Attach pull chain extensions to the pull chains 13 14 Single pin Connectors Switch Housing Screw Reverse Switch Notch To install the fan without the light kit skip to step 17 13 Remove the three switch housing screws from the top edge of the light kit Then connect the single pin connectors from the fan to the single pin connectors from the light kit blue to b...

Страница 9: ...an help move stagnant hot air off the ceiling area Reverse Switch 18 18 Restore power at the main fuse or circuit breaker 17 INSTALLATION WITHOUT LIGHT KIT OPTIONAL a Remove the three switch housing screws from the switch housing at the top of the light kit b Attach the switch housing cap to the switch housing using the three previously removed switch housing screws Note Align the notch in the swi...

Страница 10: ...om Solid State variable speed controls DO NOT USE a Solid State variable speed control 1 Ensure all blades are screwed firmly into blade arms 2 Ensure all blade arms are tightened securely to motor 3 Ensure canopy and mounting bracket are tightened securely to outlet box and outlet box is mounted firmly to ceiling joist 4 Switch one blade with a blade from the opposite side Or balance the fan usin...

Страница 11: ...e of any kind including any incidental or consequential damages resulting directly or indirectly from any breach of warranty express or implied or any other failure of this product Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you If the original purchaser ceases to own the fan this warranty is voided Should the purc...

Отзывы: