SYMPTOM
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Motor will not run
Disconnect switch is off
Be sure switch is on
Fuse is blown
Replace fuse
Starting switch is defective
DISCONNECT POWER; Replace starting switch.
Wires at motor are loose,
Refer to instructions on wiring. DISCONNECT POWER; check and tighten all wiring.
disconnected, or wired incorrectly
Pressure switch contacts are dirty
DISCONNECT POWER and file contacts with emery board or nail file.
Motor runs hot and
Motor is wired incorrectly
Refer to instructions on wiring
overload kicks off
Voltage is too low
Check with power company. Install heavier wiring if wire size is too small
(See Electrical / Wiring Chart)
Pump cycles too frequently
See section below on too frequent cycling.
Motor runs but no
*Pump in new installation did
In new installation:
water is delivered
not pick up prime through:
1. Improper priming
1. Re-prime according to instructions
2. Air leaks
2. Check all connections on suction line, AVC and ejector.
3. Leaking foot valve
3. Replace foot valve
* (Note: Check prime
*Pump has lost prime through:
In installation already in use:
before looking for
1. Air leaks
1. Check all connections on suction line and shaft seal
other causes. Unscrew
2. Water level below suction of pump
2. Lower suction line into water and re-prime. if receding water level
priming plug and see
in well exceeds suction lift, a deep well pump is needed
if water is in priming
Ejector or impeller is plugged
Clean ejector or impeller according to instructions.
hole).
Check valve or foot valve is stuck
Replace check valve or foot valve
in closed position
Pipes are frozen
Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Foot valve and/or strainer are
Raise foot valve and/or strainer above well bottom
buried in sand or mud
Pump does not
Water level in well is lower than estimated
A deep well jet pump may be needed (over 20 ft. (6 M) to water)
deliver water to full
Steel piping (if used) is corroded or
Replace with plastic pipe where possible, otherwise with new steel pipe
capacity
limed, causing excess friction
Offset piping is too small in size
Use larger offset piping
Pump delivers water but
Pressure switch is out of adjustment or
DISCONNECT POWER; adjust or replace pressure switch.
does not shut off.
contacts are 'frozen'.
Faucets have been left open.
Close faucets.
Venturi, nozzle or impeller is clogged.
Clean venturi, nozzle or impeller.
Water level in well is lower than estimated.
Check possibility of using a deep well jet pump.
Pump cycles too
Standard pressure tank is waterlogged and
Drain tank to air volume control port. Check AVC for defects. Check for
frequently.
has no air cushion.
air leaks at any connection.
Pipes leak.
Check connections.
Faucets or valves are open.
Close faucets or valves.
Foot valves leak.
Replace foot valve.
Pressure switch is out of adjustment.
Adjust or replace pressure switch.
Air charge too low in pre-charged tank.
DISCONNECT POWER and open faucets until all pressure is relieved. Using tire
pressure gauge, check air pressure in tank at valve stem located on the tank.
If necessary, pump air into tank from outside source until air pressure is
equal to cut-in setting of switch. Check air valve for leaks, using soapy
solution, and replace core if necessary.
Air spurts from faucets.
Pump is picking up prime.
When pump picks up prime, all air will be ejected.
Leak in suction side of pump.
Suction pipe is sucking air. Check joints.
Well is gaseous.
Change installation as described in manual.
Intermittent over-pumping of well.
Lower foot valve if possible, otherwise restrict pump discharge.
(Water drawn down below foot valve.)
TROUBLESHOOTING CHART
Capacitor voltage may be hazardous. To discharge capacitor,
hold insulated handle screwdriver BY THE HANDLE and short
capacitor terminals together. Do not touch metal screwdriver blade or capacitor
terminals. If in doubt, consult a qualified electrician.