SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Motor will not run

Disconnect switch is off

Be sure switch is on

Fuse is blown

Replace fuse

Starting switch is defective

DISCONNECT POWER; Replace starting switch.

Wires at motor are loose, 

Refer to instructions on wiring. DISCONNECT POWER; check and tighten all wiring.

disconnected, or wired incorrectly

Pressure switch contacts are dirty

DISCONNECT POWER and file contacts with emery board or nail file.

Motor runs hot and 

Motor is wired incorrectly

Refer to instructions on wiring

overload kicks off

Voltage is too low

Check with power company. Install heavier wiring if wire size is too small  
(See Electrical / Wiring Chart)

Pump cycles too frequently

See section below on too frequent cycling.

Motor runs but no 

*Pump in new installation did 

In new installation:

water is delivered 

not pick up prime through: 

1. Improper priming 

1. Re-prime according to instructions

2. Air leaks

2. Check all connections on suction line, AVC and ejector.

3. Leaking foot valve

3. Replace foot valve

* (Note: Check prime

*Pump has lost prime through:

In installation already in use:

before looking for 

1. Air leaks

1. Check all connections on suction line and shaft seal

other causes. Unscrew

2. Water level below suction of pump

2. Lower suction line into water and re-prime. if receding water level 

priming plug and see

in well exceeds suction lift, a deep well pump is needed

if water is in priming

Ejector or impeller is plugged

Clean ejector or impeller according to instructions.

hole).

Check valve or foot valve is stuck 

Replace check valve or foot valve

in closed position
Pipes are frozen

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

Foot valve and/or strainer are 

Raise foot valve and/or strainer above well bottom

buried in sand or mud

Pump does not 

Water level in well is lower than estimated

A deep well jet pump may be needed (over 20 ft. (6 M) to water)

deliver water to full 

Steel piping (if used) is corroded or 

Replace with plastic pipe where possible, otherwise with new steel pipe 

capacity

limed, causing excess friction
Offset piping is too small in size

Use larger offset piping

Pump delivers water but

Pressure switch is out of adjustment or

DISCONNECT POWER; adjust or replace pressure switch.

does not shut off.

contacts are 'frozen'.
Faucets have been left open.

Close faucets.

Venturi, nozzle or impeller is clogged.

Clean venturi, nozzle or impeller.

Water level in well is lower than estimated.

Check possibility of using a deep well jet pump.

Pump cycles too

Standard pressure tank is waterlogged and

Drain tank to air volume control port. Check AVC for defects. Check for

frequently.

has no air cushion.

air leaks at any connection.

Pipes leak.

Check connections.

Faucets or valves are open.

Close faucets or valves.

Foot valves leak.

Replace foot valve.

Pressure switch is out of adjustment.

Adjust or replace pressure switch.

Air charge too low in pre-charged tank.

DISCONNECT POWER and open faucets until all pressure is relieved. Using tire 
pressure gauge, check air pressure in tank at valve stem located on the tank.
If necessary, pump air into tank from outside source until air pressure is  
equal to cut-in setting of switch. Check air valve for leaks, using soapy 
solution, and replace core if necessary.

Air spurts from faucets.

Pump is picking up prime.

When pump picks up prime, all air will be ejected.

Leak in suction side of pump.

Suction pipe is sucking air. Check joints.

Well is gaseous.

Change installation as described in manual.

Intermittent over-pumping of well.

Lower foot valve if possible, otherwise restrict pump discharge.

(Water drawn down below foot valve.)

TROUBLESHOOTING CHART

Capacitor voltage may be hazardous. To discharge capacitor,

hold insulated handle screwdriver BY THE HANDLE and short

capacitor terminals together. Do not touch metal screwdriver blade or capacitor
terminals. If in doubt, consult a qualified electrician.

PUMP REASSEMBLY

1

2

3

4

5

Press in seal. Do not nick or
scratch seal faces.

Hold motor fan

Do not overtighten.

Содержание HYDRO-GLASS 390.250290

Страница 1: ...fore Start ing The Installation Save This Manual For Future Reference Sears Roebuck and Co Chicago IL 60684 U S A Installation Operation Repair Parts PRINTED IN U S A HYDRO GLASS SHALLOW WELL JET PUMP...

Страница 2: ...childproof use padlocks and master switches remove starter keys MADE IN U S A OF U S AND FOREIGN COMPONENTS Sold by Sears Roebuck and Co Chicago IL 60684 2 FULL ONE YEAR WARRANTY ON SHALLOW WELL JET...

Страница 3: ...cted to pump to prevent pump breakage 3 Wrap 1 1 2 to 2 layers of Teflon tape clockwise as you face end of pipe on all male threads being attached to pump 4 Tighten joints hand tight plus 1 1 2 turns...

Страница 4: ...pply voltage must be within 10 of name plate voltage Incorrect volt age can cause fire or seriously damage motor and voids warranty If in doubt consult a licensed electrician Use wire size specified i...

Страница 5: ...pump it may be necessary to reprime unit 2 3 times before all air is out of suction pipe 3 If after priming pump several times and no water is pumped make sure that a Suction pipe end is in water b S...

Страница 6: ...Barb 16 U36 36ZP U36 36ZP 8 Nut 17 U37 665P U37 665P 1 Pressure Switch Tube 18 2764 2781 1 Pressure Switch 19 U36 112ZP U36 112ZP 1 Lock Ring 20 L43 5C L43 5C 1 Connector F642 9206 F642 9206 1 Owner s...

Страница 7: ...deliver water to full Steel piping if used is corroded or Replace with plastic pipe where possible otherwise with new steel pipe capacity limed causing excess friction Offset piping is too small in s...

Страница 8: ...Connection WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION MODEL NUMBER NAME OF ITEM All parts listed may be ordered from any Sears Service Center If the...

Отзывы: