background image

ELECTRICAL

PIPING

INSTALLATION

Horizontal Piping From Well To Pump

When the pump is offset more than 25 feet from the well,
horizontal piping should be increased in size to reduce fric-
tion losses. In no case should the offset piping be smaller
than the suction tapping of the pump.

Horizontal Offset Piping Sizes for Shallow Well Jets

1-1/4”

1-1/2”

2”

Up to 25 Ft.

25 to 50 Ft.

50 to 200 Ft.

Discharge Pipe Sizes

When the pump is set at a distance from the house or point
of water use, the discharge pipe size should be increased to
reduce pressure losses caused by friction.

1”

1-1/4”

1-1/2”

Up to 25 Ft.

25 to 100 Ft.

100 to 600 Ft.

If horizontal suction pipe is more than 25’ long, install a
priming plug at well head to allow filling of pipe.

SEARS jet pumps should be used with Captive Air® Tanks
(see Figure 2, Page 3). For  mounting pump to tank, pur-
chase tank fittings Kit No. 2788.

SEARS Captive Air® Tanks are pre-charged with air at the
factory. Check the tank Owner’s Manual to find if air charge
needs adjustment. Model 390.250284 requires 30 pounds
for proper operation.

The Jet pump can also be mounted on standard horizontal
tanks. A mounting kit with an AVC is furnished with tank
(Figure 1, Page 3). Instruction are also included.

The installation, operation and care of your Hydroglass®
pump is very similar to cast iron pumps. We ask, however,
that you keep the following points in mind.

IMPORTANT: Use teflon tape supplied with the pump
for making all threaded connections to the pump it-
self. Do not use pipe joint compounds on the pump!

1. Wrap one and one-half to two layers of Teflon tape on all

male threads being attached to pump. This will insure
leakproof connections. Do not overtighten threaded fit-
tings in the plastic pump. If leaks do occur, remove the
fitting, 

clean off 

the old Teflon tape, rewrap with one

and one-half to two layers of new tape and remake the
connection.

2. Be sure to support all piping connected to your Shallow

Well Jet Pump.

3. To connect AVC to the pump, remove the 1/8” pipe plug

(Key No. 13, Page 11) from the jet portion of the pump
body near the suction tapping. Insert a 1/8” fitting into
this tapping. Cut tubing to length and assemble the two
fittings on the air volume control and pump body.

4

Distance in Feet From Motor to Meter

Branch*

0’

51’

101’

201’

201’

401’

Motor

Max.

Fuse

to

to

to

to

to

to

Horse-

Load

Rating

50’

100’

200’

300’

400’

500’

power

Volts

Amperes

Amps

Wire Size

1/2

115/230

10.4/5.2

15/15

14/14

14/14

10/14

8/14

6/14

6/12

TABLE II: WIRING CHART – Recommended Fusing and Wiring Data

* Time delayed fuses are recommended instead of regular fuses in any motor circuit.

Figure 3

Priming
Tee and
Plug

Well
Casing

Foot
Valve

Sanitary
Well Seal

Suction Pipe
From Well

Foot
Valve

Screen

10'

Min.

5–10'

Cased
Well

Open
Water

Strainer

1836 0695

Содержание CRAFTSMAN HYDROGLASS 390.250284

Страница 1: ...Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Operation Troubleshooting Repa...

Страница 2: ...izing is essential to proper motor operation Recommended fusing and wire size data is in the manual Page 5 11 Pump water only with this pump 12 Periodically inspect pump and system components Motor no...

Страница 3: ...ot valve and strainer should be installed for easy priming It should be five to ten feet below the lowest level to which the water will drop while pump is operating pumping water level The strainer sh...

Страница 4: ...pump is very similar to cast iron pumps We ask however that you keep the following points in mind IMPORTANT Use teflon tape supplied with the pump for making all threaded connections to the pump it s...

Страница 5: ...switch as shown in Figure 4 5 FIGURE 4 Motor wiring connections through Pressure Switch Match motor voltage to line voltage Your Motor Terminal Board under the motor end cover and Pressure Switch look...

Страница 6: ...o a point below the freeze line To drain an air volume control AVC remove the tubing from it and turn the AVC upside down This will permit any water in the AVC to drain into tank Disassembly and Assem...

Страница 7: ...eum jelly or de tergent solution C With finger pressure press firmly and squarely into cavity Polished face of seat faces inside of pump If seat will not locate properly place cardboard washer over po...

Страница 8: ...Page 11 stays in place on top of diffuser Installing Copper Insert NOTE If the copper insert Key No 4 Page 11 moves or shifts during seal removal it should be removed and rein stalled 1 Remove copper...

Страница 9: ...ction as the dislodging tool was inserted 4 Replace nozzle and venturi Do not overtighten 5 Reassemble per pump instructions on Page 6 HELPFUL HINTS How to Handle a Gaseous Well In some areas well wat...

Страница 10: ...es not 1 Water level in well is lower than 1 A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with p...

Страница 11: ...C78 41T 1 Pipe Plug 1 8 NPT 14 U111 212T 2 90 Hose Barb 15 U37 669P 1 Switch Tube 16 J20 18 1 Gasket 17 N76 29P 1 Pump Body Jet Insert 18 U30 742SS 4 Capscrew 10 16 19 N34P 19 1 Nozzle 45 20 N32P 66 1...

Страница 12: ...5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIR...

Отзывы: