Clean and lubricate trap cover O-ring with petroleum jelly
each time it is removed.

Clean and inspect O-ring; reinstall on trap cover.

Replace trap cover on trap; turn clockwise to tighten
cover.

NOTICE: 

Tighten trap cover by hand only 

(no wrench-

es).

Use a lever or lid wrench only if necessary to remove

cover.

Pump should prime. Priming time will depend on vertical
length of suction lift and horizontal length of suction pipe.

If pump does not prime within ten minutes, stop motor
and determine cause. Be sure all suction and discharge
valves are open when pump is running. See Troublesho-
oting Guide.

Storage / Winterizing

Explosion hazard. Purging the system

with compressed air can cause components to ex-
plode, with risk of severe injury or death to anyone
nearby.

Use only a low pressure (below 5 PSI), high vol-

ume blower when air purging the pump, filter, or piping.

NOTICE:

Allowing pump to freeze will void warranty!

NOTICE: Do not

use anti-freeze solutions (except propy-

lene glycol) in your pool/spa system. Propylene glycol is
non-toxic and will not damage plastic system compo-
nents; other anti-freezes are highly toxic and may damage
plastic components in the system.

Drain all water from pump and piping when expecting
freezing temperatures or when storing pump for a long
time (see instructions below).

Gravity drain system as far as possible.

Protect areas which retain water with non-toxic propy-
lene glycol antifreeze (“RV antifreeze”).

Keep motor dry and covered during storage.

To avoid condensation/corrosion problems, 

do not

cover

or wrap pump with plastic film or bags.

For outdoor/unprotected pump installations:

1.

Enclose entire system in a weatherproof enclosure.

2.

To avoid condensation/corrosion damage, allow venti-
lation; 

do not 

wrap system in plastic film.

3.

Use a 40% propylene glycol/60% water solution to pro-
tect pump to -50 degrees F.

Draining Pump

1. Pump down water level

below all inlets to the pool.

To avoid dangerous or

fatal electrical shock

hazard, turn OFF power to
motor before draining
pump.

2. Remove trap cover and use

low pressure air to blow ac-
cumulated water from the
piping system.

3. Cap inlet piping after drain-

ing to keep water out of
the pipes.

4.

To prevent pump from freezing, remove trap cover and
drain the tank body through the drain plug (Key No.
17, Page 11). Use a lid wrench to remove trap covers
that have been overtightened or have taken a set and
cannot be removed by hand. Clean pump thoroughly.
Replace trap cover.

5.

Be sure motor is kept dry and covered.

Startup For Winterized Equipment

1.

Remove any temporary weather protection placed
around system for shutdown.

2.

Follow filter manufacturer’s instructions for reactiva-
tion of the filter.

3.

Inspect all electrical wiring for damage or deterioration
over the shutdown period. Have a qualified service-
man repair/replace wiring as needed. 

4.

Inspect and tighten all watertight connections.

5.

Open all valves in suction and return piping.

6.

Remove any winterizing plugs in piping system.

7.

Drain all anti-freeze from system.

8.

Close all drain valves and replace all drain plugs in pip-
ing system.

9.

Prime pump according to instructions on Page 6.

OPERATION

WARNING

Hazardous voltage. Can
shock, burn, or cause
death.

Disconnect power before
working on pump or motor.

Содержание CRAFTSMAN 390.262801

Страница 1: ...perating Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Operation Service Hint...

Страница 2: ...ve limita tion or exclusion may not apply to you WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER DE PARTMENT IN THE UNITED STATES This warranty applies only while t...

Страница 3: ...rns about hazards that can cause serious personal injury death or major property damage if ignored CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignore...

Страница 4: ...ape rewrap with one to two additional layers of tape and remake con nection NOTICE Support all piping connected with pump Piping For pump discharge use 1 1 2 PVC pipe or reinforced hose For pump sucti...

Страница 5: ...ground Bond motor to pool structure Use a solid copper con ductor size No 8 AWG 8 4 mm2 or larger Run wire from external bonding lug see Figure 2 to reinforcing rod or mesh FIGURE 2 Typical ground scr...

Страница 6: ...lute and trap with water before starting motor Do not add chemicals to pool spa system di rectly in front of pump suc tion Adding undiluted chemicals may damage pump and voids warranty Before removing...

Страница 7: ...not cover or wrap pump with plastic film or bags For outdoor unprotected pump installations 1 Enclose entire system in a weatherproof enclosure 2 To avoid condensation corrosion damage allow venti la...

Страница 8: ...10 Replace if material shows any sign of damage or deterioration 2 Check the mechanical seal Key No 6 Page 10 for scoring on the contact surfaces and also for any dam age to the spring or retainer Rep...

Страница 9: ...for proper voltage 7 Check GFCI for proper operation according to GFCI manufacturer s instructions Mechanical Troubles Noise 1 Make sure suction and discharge piping are supported 2 Securely mount pu...

Страница 10: ...C3 139P1 C3 139P1 10 Trap Cover O Ring U9 229 U9 229 11 Trap Basket C108 33P C108 33P 12 Drain Plug 1 4 NPT with O Ring U178 920P U178 920P 13 Flat Washer 5 16 8 Req U43 41SS U43 41SS 14 Capscrew 5 16...

Страница 11: ...11...

Страница 12: ...about an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVIC...

Отзывы: