ELECTRICAL
Risk of dangerous or fatal electric
shock. Unplug pump before servicing it.
Do not handle pump or attempt to work
on pump with wet hands or while
standing on wet or damp floor.
Plug pump into 115 Volt, 60 Cycle outlet only. Pump is
equipped with 3-wire, grounded, cord and plug. Do not
modify or remove plug. Plug in to properly grounded,
grounding type outlet only. Make sure pump circuit meets
National Electrical Code (in USA) or Canadian Electrical
Code (in Canada). To avoid dangerous electrical shock haz-
ard, keep cord dry at all times.
Hazardous
voltage
5
2377 0396
2378 0396
Figure 5 – Capacitor replacement. Unplug pump
before doing any work on it. Discharge capacitor
by shorting capacitor lead wires together before
removing it.
Figure 6 – Shroud replacement. Unplug pump
before doing any work on it. Be sure that green
ground wire is solidly connected to grounding
terminal (marked
) before reinstalling
shroud. See Steps 1 and 10, Page 6, for shroud
fastenings.
Gal.
per
Min.
Discharge Pressure in Pounds per Square Inch
Suction
5
10
15
20
25
30
35
40
Lift
Flow in Gallons Per Minute
0' 10.2
10.0
9.7
9.2
8.4
6.9
5.6
4.2
5' 9.9
9.6
9.4
9.1
7.5
6.1
4.9
3.8
10'
7.9
7.6
7.4
7.2
6.3
5.3
4.0
3.0
15' 6.5
6.4
6.3
6.2
6.0
4.5
3.4
2.5
20' 4.8
4.8
4.8
4.7
4.7
4.2
3.1
2.2
Performance Chart
NOTE:
Performance does not take into account pressure losses in suction and discharge piping.
}