MAINTENANCE

8. Hold the motor shaft with pliers or vice grips

through the opening in the pump adapter. Unscrew
the impeller nut off the end of the shaft (see Figure
23).

9. The impellers are keyed to the shaft and do not un-

screw. Insert two screw drivers on opposite sides
under the exposed impeller and pry the impeller
off (Figure 24) to remove it.

10. Carefully tap a small screwdriver or thin bladed

chisel in between the intermediate volute and the
pump adapter in two or three places around the
pump to separate the castings (Figure 25).

Do not

mar the sealing surfaces; do not break pieces out
of the adapter or volute – the castings are easily
damaged.

11. Remove the intermediate volute and slide the im-

peller spacer off of the shaft.

12. Remove the impeller. Don’t disturb the shaft keys if

you are only replacing the seal.

13. Rotate the seal spring retainer cup so that the slot

lines up with the shaft keys; remove the cup and
spring.

14. Remove the two cap screws holding the adapter

bracket to the motor.

15. With two screwdrivers on opposite sides of the

pump, carefully pry the pump adapter away from
the motor. This will pull the seal off of the motor
shaft. 

Use caution to make sure that the ceramic

seal does not dig into the shaft and scratch the
shaft’s sealing surface.

Installation Of New Seal

1. Clean all gasket surfaces thoroughly before re-

assembly. Clean the seal bore cavity in the pump
adapter.

2. Wet the rubber seat ring with soapy water and push

the stationary part of the seal into the seal bore cav-
ity. Use a piece of 1” pipe pressing on a cardboard
washer (to prevent damaging seal surface) as a
press. 

Make sure that the seal half is fully seated

in the seal bore cavity.

Remove the cardboard once

the seal is in place.

3. Make sure that the shaft keys are in place on the

shaft. If they are not, squeeze them in place now
with slip joint pliers. 

Do not tap them or hit them

with a hammer; you could bend the shaft

(see

Figure 26). When the keys are correctly installed, the
adapter will pass over the keys without interference.

13

Figure 23

Figure 24

Figure 25

Use pliers –

with care –

no hammers.

Figure 26

Содержание CRAFTSMAN 390.2532

Страница 1: ...ting Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Operation Maint...

Страница 2: ...or below at all times Over pressure can cause tank blowup in stall relief valve capable of passing full pump vol ume at 100 PSI 5 With a new well test well for purity before use Consult local Health D...

Страница 3: ...in the tank drops to 40 pounds per square inch PSI and stops the pump when the tank pressure reaches 60 PSI Adapter Flange The VMS pump is equipped with an adapter flange This adapter facilitates inst...

Страница 4: ...e Jet Package No 29902 3 Single Pipe use 1 1 4 galvanized pipe Jet Package No 29660 4 Double Pipe Must be ordered through Sears Product Service 1 800 366 7278 1096 0697 Pump Body From Well Dirt and Sc...

Страница 5: ...lastic pipe is ideal for double pipe installations Due to its light weight it is easy to handle and does not usually require a block and tackle for installation and removal Double Pipe Installation Pl...

Страница 6: ...ter flange making sure that holes line up 13 Align locating lugs on pump base with locating lugs on adapter flange attach pump to flange with cap screws provided 14 See Discharge Pipe Sizes for inform...

Страница 7: ...er installation 5 With ejector set install well casing adapter Remove pipe holder Align locating lugs and tighten adapter to form seal with well casing Discharge Pipe Sizes 1 If increasing discharge p...

Страница 8: ...a single voltage motor NOTICE Never wire a 115 volt motor to a 230 volt line Remove Motor End Cover You will need to remove the motor end cover to change the voltage setting The illustration above al...

Страница 9: ...be a solid copper wire at least as large as the power supply wires 2 There must be a solid metal connection between the pressure switch and the motor for motor grounding protection If the pressure swi...

Страница 10: ...apidly to 50 pounds per square inch or more as ejector and pump prime If so go to step 4 below If pressure does not build to 50 PSI repeat steps a b and c under Step No 1 two or three times to re move...

Страница 11: ...pump with regulator valve open HELPFUL HINTS MAINTENANCE How To Handle A Gaseous Well In some areas well water contains gases which must be allowed to escape before the water is used To deliver gas f...

Страница 12: ...cording the gauge you may have air leaks in the suction line or a clogged impeller Cleaning the Deep Well Jet 1 Disconnect power 2 Disconnect piping and well seal or casing adapter 3 Withdraw jet asse...

Страница 13: ...screws holding the adapter bracket to the motor 15 With two screwdrivers on opposite sides of the pump carefully pry the pump adapter away from the motor This will pull the seal off of the motor shaf...

Страница 14: ...the long cap screws to check this alignment It cannot be stressed too strongly that all bolt holes and water passages of all gaskets and volutes MUST line up with each other or the pump will not be as...

Страница 15: ...iring 5 Clean by sliding piece of plain paper between contacts 6 Make sure motor voltage exactly matches power supply voltage 1 Refer to instructions on wiring 2 Check with power company Install heavi...

Страница 16: ...2 Req 14B J23 10 Wear Ring 2 Req 14C J23 11 Wear Ring 15 U36 175D Impeller Nut 16 J101 33 Base Volute w Wear Ring 17 U78 57CT Pipe Plug 1 4 NPT 18 Capscrew 3 8 16x4 1 4 Lg 4 Req Repair Parts List Mult...

Страница 17: ...3 Spring 6 J61 5 Spring Guide 7 J52 9 Bonnet 8 Capscrew 5 16 18x3 4 Lg 4 Req 9 U30 69FTZP Adjusting Screw 5 16 18x2 10 U36 205ZP Locknut 5 16 18 Repair Parts List Pressure Regulator Standard hardware...

Страница 18: ...7ZP U30 277ZP 3 8 16x2 1 2 Hex Hd Bolt 3 Req 7 J21 17 J21 21 Seal Ring Lower 8 J16 20ZZP J16 24ZZP Lower Flange 9 U36 38ZP U36 38ZP 3 8 Hex Nut 3 Req Key Part No Number Part Description 1 J20 12 Adapt...

Страница 19: ...trainer 12 U11 104P Plastic Pipe Adapter J216 13 J216 14 Casing Adapter U37 116GP U37 116GP 1 x 6 T O E Nipple Max Depth with Jet Package No 2967 29902 29660 Pump Venturi 2 Single 3 Single 4 Double Mo...

Страница 20: ...or to inquire about an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialist...

Отзывы: