D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove the vent grille.
(2) Remove the mount, all.
(3) Remove the outer case.
(4) Disconnect the wireleads.
(5) Remove the three screws and
Magnetron
very
carefully.
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or damage
may occur.
• When replacing the magnetron, be sure to install
the magnetron gasket in the correct position and be
sure that the gasket is in good condition.
• After replacing the magnetron, check for
microwave energy leakage with a survey meter.
The microwave energy leakage must be below the
limit of 5 mW/cm
2
. (All service adjustments should be
made for minimum microwave energy leakage
readings.)
7-8
Figure 11
Figure 13
Figure 12
Outcase
Vent Grille
Содержание 721.81622600
Страница 36: ...7 25 PROBLEM E No buzzing when touching the key between stages or at end of cooking 1...
Страница 37: ...7 26 PROBLEM F Ventilation fan does not operate when FAN HIGH LOW key is touched 1 Check 1 POWER SUPPLY 2 FUSE...
Страница 42: ...8 5 4000 4001 4002 4003 4002 4004 W102 LATCH BOARD PARTS EV...
Страница 46: ...P NO MFL30502901...