D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove the vent grille.
(2) Remove mount, all.
(3) Remove outcase.
(4) Disconnect the wireleads.
(5) Remove the three screws and
Magnetron
very
carefully.
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
• When replacing the magnetron, be sure to install
the magnetron gasket in the correct position and be
sure that the gasket is in good condition.
• After replacing the magnetron, check for
microwave energy leakage with a survey meter
Check microwave energy leakage must be below
the limit of 5 mW/cm
2
. (All service adjustments
should be made for minimum microwave energy
leakage readings.)
7-8
Figure 11
Figure 13
Figure 12
Outcase
Vent Grille
Содержание 721.80412500
Страница 9: ...5 1 OVERALL CIRCUIT DIAGRAM SCHEMATIC DIAGRAM RY1 O L RY14 C L HIGH RY15 C L NIGHT RY11 V M RY6 T M...
Страница 10: ...5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD...
Страница 34: ...7 23 PROBLEM D No buzzing when touching the key between stages or at end of cooking 1...
Страница 35: ...7 24 PROBLEM E Ventilation fan does not operate when FAN HIGH LOW key is touched 1 Check 1 POWER SUPPLY 2 FUSE...
Страница 39: ...8 4 4000 W102 4001 4002 4003 4002 4004 LATCH BOARD PARTS EV...