-19-
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE OUTER CASE
FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH VOLTAGE CAPACITOR
AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE HIGH VOLTAGE
TRANSFORMER.
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER OF
WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 0.2 ~ 0.4 ohm
Approx.: 70 ~ 100 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
FILAMENT
WINDING
PRIMARY
TERMINAL
11. TEST AND CHECKOUT PROCEDURES, AND TROUBLESHOOTING
A. TEST PROCEDURES
Содержание 721.66339
Страница 1: ...DIVISION 20 BASIC FIELD MANUAL FOR MICROWAVE OVEN MODEL 721 66339800 February 2008 MODEL 721 66339...
Страница 9: ...B MATRIX CIRCUIT FOR TOUCH KEY BOARD 8 Figure 4...
Страница 31: ...EXPLODED VIEW INTRODUCTION 30 DOOR CONTROL PANEL BASE PLATE OUTER CASE LATCH BOARD INTERIOR SENSOR EV...
Страница 32: ...31 DOOR PARTS 1004 1000 1005 1007 1006 1002 1013 1003 1001 EV...
Страница 33: ...32 CONTROLLER PARTS 2000 2002 2006 W106 2004 2381 EV...
Страница 34: ...33 OVEN CAVITY PARTS 3002 W107 W103 3001 3003 3008 3009 W105 3034 EV...
Страница 35: ...34 LATCH BOARD PARTS W102 4002 4003 4002 4004 4000 4001 EV...
Страница 37: ...36 BASE PLATE PARTS 5008 W101 W108 6000 6007 6001 EV...
Страница 38: ...37 SENSOR PARTS W136 5011 5004 W108 EV...
Страница 39: ...P NO MFL30502909 Printed in Korea...