7-21
PROBLEM - A:
PLEASE SET TIME OF DAY
does not appear in display window when power supply cord is
plugged into wall outlet.
PROBLEM - B:
Display does not show correct numbers and/or
correct indications when programmed.
Check: 1. POWER SUPPLY
2. FUSE (See
CHECKOUT PROCEDURES FOR FUSE BLOWING: on page 7-18)
3. OVEN CAVITY THERMOSTAT
1
1
C. TROUBLE SHOOTING
Before following this troubleshooting read
TRIAL
OPERATION
on page 6-1.
¥
DISPLAY
Problems,
A
thru
C
¥
HELP UP
Problems,
D
thru
E
¥
BUZZER Problems,
F
Measure voltage between pin 1
and pin 3 of connector CN1.
Measure resistance of touch
key board after removing
connector S1.
(See page 7-4 and 7-17)
0
120
120V
Replace
circuit board
Normal
circuit board
Normal
resistance
Voltage
incorrect
Normal
resistance
Resistance
incorrect
Replace touch
key board.
Normal touch
key board
Poor
contact
Correct
seating
Contact
ok
Replace
circuit board
Normal
circuit board
Normal
contact
Check contact
of connector S1
Correct
connections
0
120
WH
RD
Runs
Runs
Runs
Runs
Runs
Содержание 721.63652300
Страница 9: ...5 1 OVERALL CIRCUIT DIAGRAM SCHEMATIC DIAGRAM I Check the Model No...
Страница 10: ...5 2 SCHEMATIC DIAGRAM II Check the Model No ADD Noise filter...
Страница 41: ...8 4 LATCH BOARD PARTS 4001 W111 4000 4002 4003 4002 4004 EV...
Страница 45: ...8 8 INSTALLATION PARTS 6008 6010 6011 6009 VINYL BAG EV...
Страница 46: ...P NO 3828W5S4598 Printed in Korea...