background image

INSTALLATION

5

Pump Installation

SEARS jet pumps can be used with SEARS Captive Air

®

Tanks as shown in Figure 2, Page 4.

For mounting pump to tank, order tank fitting Kit No.
2788.

SEARS Captive Air

®

Tanks are precharged with air at the

factory. Check the tank Owner’s Manual to find if air
charge needs adjustment. Your pump requires 20
pounds for proper operation.

The SEARS jet pump can also be mounted on standard
horizontal tanks. A kit consisting of all necessary pip-
ing, elbows, and other fittings, is furnished with the
tank for mounting pump using this method. See Figure
3, Page 4. Instructions are included with tank.

Air Volume Control – 
Included With Standard Horizontal Tank

There is a 1-1/4” x 1/4” reducer bushing and a 1/4” x
1-1/2” nipple supplied in the fittings package. Use the
one that fits into the air volume control tapping in the
end of the tank as shown in Figure 3, Page 4. Use pipe
compound on male threads. Screw the air volume con-
trol on to the 1/4” fitting and the right angle compres-
sion fitting into the bottom tapping of the air volume
control.

Remove the 1/8” pipe plug, Key No. 15, Page 10, on
the jet portion of the pump body near the check valve.
Insert a 1/8” compression fitting into this tapping. Cut
tubing to length and assemble the two fittings in the
air volume control and pump body. Use nuts, sleeves,
and inserts furnished.

Priming the Pump

Never run pump dry. Running pump

without water may cause pump to

overheat, damaging seal and possibly causing
burns to persons handling pump.

Fill pump with

water before starting.

Never run pump against closed dis-

charge. To do so can boil water inside

pump, causing hazardous pressure in unit, risk
of explosion and possibly scalding persons han-
dling pump.

DO NOT START MOTOR UNTIL PUMP HAS BEEN
FILLED WITH WATER.

1. Remove the priming plug. fill pump with water.

Replace priming plug. If a priming tee and plug
have been provided for a long horizontal run, be
sure this line is filled and the plug replaced, using
pipe compound on plug threads. See Figure 3, Page
4.

2. Start the pump. Water will be pumped in a few min-

utes; the time depending upon the depth to water,
and the distance of horizontal run. If pump does
not prime, check for a possible leak on the suction
side of the pump. Reprime. Check to be sure suc-
tion lift – distance from water level to pump – does
not exceed 20 feet.

Содержание 390.250252

Страница 1: ...tructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance Repair Part...

Страница 2: ...l current supply agree with the motor wiring as shown on motor nameplate 10 The correct fusing and wiring sizing is essential to proper motor operation Use recommended fusing and wire size data in the...

Страница 3: ...sediment may clog it Before installing foot valve check to see that it work freely When using a foot valve a priming tee and a plug as shown in Figure 1 is recommended Be sure the total lift from the...

Страница 4: ...ed if horizontal piping is 25 ft or more Drive Coupling Check Valve Driven Point 1 1 4 Steel Drive Pipe Priming Tee To Service Pressure Switch From Well Built in Check Valve Plastic pipe Adapter Air V...

Страница 5: ...e the 1 8 pipe plug Key No 15 Page 10 on the jet portion of the pump body near the check valve Insert a 1 8 compression fitting into this tapping Cut tubing to length and assemble the two fittings in...

Страница 6: ...motor connect ground screw in switch to motor ground screw Use a solid copper wire at least as large as power supply wires Connect ground wire to grounded lead in service panel metal underground water...

Страница 7: ...3 Carefully tap diffuser to remove from seal plate 4 Remove canopy from end of motor 5 Partially unscrew capacitor clamp move capacitor to one side 6 Hold motor shaft with 7 16 wrench on the flats on...

Страница 8: ...p body 3 Insert an ice pick or other small diameter pointed tool through the venturi and into the nozzle This will dislodge foreign material 4 Foreign material will drop to the bottom of the pump body...

Страница 9: ...uried in sand or mud Pump does not 1 Water level in well is lower than 1 A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is...

Страница 10: ...76 21TF 1 Pump Body Assembly 14 N212 12P 1 Check Valve 15 U78 56CT 1 Pipe Plug 1 8 NPT Square Head 16 U78 57CT 1 Pipe Plug 1 4 NPT Square Head 17 U30 75ZP 4 Capscrew 3 8 16x1 1 4 Hex Head 18 U37 672P...

Страница 11: ...ing Elbow 1 4 NPT 39 U111 100T Compression Fitting Straight 1 8 NPT Standard hardware item May be purchased locally Sears Shallow Well Jet Pump Air Volume Control Package Not Furnished Must be purchas...

Страница 12: ...bout an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES...

Отзывы: