ELECTRICAL COnnECTIOnS, CABLE COnnECTIOnS and OPERATIOn

White: Pin 4 = (–) Pulse
Blue: Pin 3 = (+) Pulse
Black: Pin 2 = (–) Power
Brown: Pin 1 = (+) Power

Gray:  Pin  5  =  Ground

Shield Drain Wire

CABLE COnnECTIOnS

ELECTRICAL COnnECTIOnS

WMP104.

 The WMP104 is battery-powered totally self-con-

tained and does not require any electrical connections.

WMP101.

 A connector is provided on the outside of the 

WMP101. If the output cable has been ordered, follow the 
diagram below to make connections to it. To connect to the 
meter, plug the connector in and hand tighten the retaining 
threads. A cable with connector can also be ordered from 
any Turck sensor dealer, part no. RK4.5T-6/S618 (6 meter 
length) or equivalent. Follow the diagram to make connec-
tions.  If  you  are  using  the  pulse  output,  connect  power 
first and determine that the meter is working properly by 
observing the display. Then connect the pulse output.

OPERATIOn

Grounding (WMP101). 

For best performance, especially 

in  chemically  noisy  environments,  the  gray  ground  wire 
and the bare drain wire should be connected together and 
to a good earth ground as close to the meter as possible. 
Metal pipe and fittings in contact with the fluid should also 
be bonded to the same earth ground with corrosion-resis-
tant connections.

Display.

 The display reads flow rate and accumulated to-

tal, in the units for which it was ordered. The top line is 
total, the bottom line is rate, and indicators give the units 
(ac-ft, GPM for instance.) Empty or partially-full pipe is au-
tomatically  detected  and  is  indicated  by  a  reading  of  “ 
– EP – “.

Battery. 

Estimated battery life is one to ten years depend-

ing on usage, application, and power options selected dur-
ing purchase. On the battery-powered WMP104 there is a 
low-battery indicator (“low bat”) when the battery voltage 
drops below a certain point. Batteries should be changed 
within four weeks of the appearance of this indicator.

5

Содержание WMP-Series

Страница 1: ...WMP Series PLASTIC BODIED MAGMETER instructions W M P S eries P L A S T I C B O D I E D M A G M E T E R i n str u ctio n s 2 inch 1 inch ...

Страница 2: ...Flow rate and total can be displayed in a variety of units customer selected and factory set The WMP Series is used for tracking flow rate and total flow in usage monitoring applications for instance in compliance with regulatory requirements These would include wells industrial wastewater heap leach mining discharge cooling tower deduct metering turf and landscape applications and other water rec...

Страница 3: ...unregulated power supply 18 Vdc may damage the meter due to AC line input voltage fluctuation 6 each AA alkaline cells replaceable Estimated life is 1 year with meter in typical use or 3 years dry 2 each C lithium batteries replaceable Estimated life is 3 years with meter in typical use or 10 years dry Current sinking pulse opto isolated 24 Vdc at 10 mA max 1 gal pulse out or 1 liter pulse out dep...

Страница 4: ...eametrics Follow the diagram below to make the connections Position This is an all position meter which can be installed either vertically or horizontally register up down or angled However entrained air or solids may make some positions preferable to others See the position diagram for guidance Less Ideal Air bubbles and sediment on the electrodes can affect accuracy Intermittent air bubbles pass...

Страница 5: ...deal Air can be trapped Not Ideal Post valve cavitation can create air pocket Recommended Allows air to bleed off Recommended Keep pipe full at meter for accuracy Recommended Keeps pipe full at meter for accuracy WMP WMP WMP WMP WMP WMP 1X 5X 5X Expanded Pipe Swirling Flow Partially Open Butterfly Valve 1X WMP WMP Reduced Pipe 4 ...

Страница 6: ...the display Then connect the pulse output Operation Grounding WMP101 For best performance especially in chemically noisy environments the gray ground wire and the bare drain wire should be connected together and to a good earth ground as close to the meter as possible Metal pipe and fittings in contact with the fluid should also be bonded to the same earth ground with corrosion resis tant connecti...

Страница 7: ... in place Be care ful not to lose the wash ers Move the top cover to one side and remove the foam retainer which covers the battery tray or pack For units with AA alkaline batteries remove the old bat teries from the battery tray and replace them with fresh ones taking care to fol low the polarity indicators in the battery tray For units with C lithium batteries carefully unplug each of the two ba...

Страница 8: ...LT 65200337 B 4 12 10 Seametrics Incorporated 19026 72nd Avenue South Kent Washington 98032 USA P 253 872 0284 F 253 872 0285 1 800 975 8153 www seametrics com ...