background image

PAGE

 

6

 

 

 

Pump Storage:  
 

 

Check the pressure setting before you remove or turn off the air pump. If you used to change the pressure 
setting, the pump will remember this new setting when starting up next time. 

 

Disconnect the power or turn off the power switch of the air pump. Clean all dirt, sand, etc from the pump. 
If the pump gets wet, let it dry in the air before packing it into the carrying bag. 

 

Best to store your pump in a temperature range 5 ºC - 20ºC (40ºF - 68ºF), 

 

For a Lead Acid type battery, you should fully charge the battery before storing. Leaving the battery in a 
poorly charged state for extended periods of time (1 month or more) will damage the battery.  

 

If you fully charged the pump just prior to storing it, there should be no need to recharge it for months. 

 

If you see a Low Battery icon on the LCD screen, please recharge the battery within 24 hours. If the battery 
will not hold a charge any more, the battery may need to be replaced in most case.  

 

Additional works on valve adaptor and air filter 

 

 

We may install the HR/BRAVO type universal valve adaptor onto the yellow hose. You may switch to 
another air valve adaptor by twisting off the attached one. If you wish to permanently attach a valve 
adaptor, you may use electric tape on the air valve adaptor to make it fit tight.  

 

Replacement Parts List 

 
Please contact seller if you need parts for replacement.  (1) Air hose; (2) Air valve adaptors; (3) Lead Acid 
battery pack; (4) 110-240 Lead Acid Battery AC Charger ( 14V ); (5) Power cord (80D); (4) Carrying bag (80D 
or 80DB);  (5) Turbine fan & motor unit; (6) Cylinder unit for 2

nd

 stage; (7) motor for cylinder; (8) Electric 

sensor for air pressure; (9) LCD display control board (10) Power relay control board. (11) Other Parts. 
 

 

2 Years Limited Warranty 

 

 

For recreational using, the electrical control boards, motor, charger are guaranteed for 2 years. Battery, air 
hose, valve adaptors and carrying bag are guaranteed for 6 months. 

 

Warranty for commercial use is limited to six months from purchase date, and 30 days warranty for battery. 

 

Warranty only covers the defective factory parts under normal operating conditions. You can contact the 
seller to get authorization before return it. Dealer has the right to refuse the warranty claim if the product 
shows excessive wear, abuse or misuse. 

 

Seller will pay for the two way shipping costs if the warranty claim is within 60 days from the date of 
purchase. Customer will pay for the one way shipping cost if the warranty claim is after 60 days from date 
of purchase and within 6 months. Customer will pay for the two ways shipping cost if the warranty claim is 
over 180 days from the date of purchase.  

 

Only Seamax will give 2 years warranty for the pumps we sold.  Seamax will service all the pumps in 
Canada. Address: 120-11791 Machrina Way, Richmond, BC, Canada.  Tel: 604-277-7766.  

 

Please keep your receipt and the labels on the pump for your warranty service.  We offer all the repair 
service for the pump after the warranty period. 

Содержание 80D/GP120

Страница 1: ... Machrina Way Richmond BC Canada V7A 4V3 support seamaxmarine com Important Safety Instructions To guard against injury basic safety precautions should be observed To avoid possible electrical shock or fire special care should be taken when using near the water or metal Don t use the pump close to your Fuel Tank or An Open Flame Please make sure the pump with correct pressure setting for your cham...

Страница 2: ...g time is limited to 15 minutes Long periods of use can cause overheating and damage the inflator Smaller valve fittings can limit the airflow speed the pump could be easier to get overheat Your attention is very important and the pump continued working time must be reduced Low quality power source will slow down a lot pump running at high pressure 2nd stage it can cause the pump over heat quickly...

Страница 3: ...ing The Boston type Leafield C7 air valve use a built in rubber diaphragm or diaphragm spring they will cause excessive back pressure When inflating chambers with this style of valve you must monitor the pump closely This style of valve causes the pump to overheat prematurely because of the back pressure caused by the valve diaphragm This back pressure will give the pump s sensor a false reading a...

Страница 4: ...KPa and PSI 10KPa 100mbr 1 45 PSI Factory default working pressure is set as 25KPa 3 6 PSI This pressure is suitable for most inflatable boats Min set pressure is 1 PSI 8Kpa if you only need lower pressure than 1 PSI you can keep monitoring the screen pressure reading and stop the pump manually Press the POWER button to start During inflation the left hand side of LCD screen should show the pressu...

Страница 5: ...ger The type of this battery is 12V gel battery lead acid type battery capacity 7AH The battery will have up to 500 Cycles up to 8 years battery life time if you can follow this maintenance manual Always keep the pump battery 80DB full charged before putting at storage or after every use The charger is 110 240V travel type with double charging procedures When you plug in the charge and connect wit...

Страница 6: ...ir hose 2 Air valve adaptors 3 Lead Acid battery pack 4 110 240 Lead Acid Battery AC Charger 14V 5 Power cord 80D 4 Carrying bag 80D or 80DB 5 Turbine fan motor unit 6 Cylinder unit for 2nd stage 7 motor for cylinder 8 Electric sensor for air pressure 9 LCD display control board 10 Power relay control board 11 Other Parts 2 Years Limited Warranty For recreational using the electrical control board...

Страница 7: ...LTAGE DC 11 0V MAX OPERATION VOLTAGE DC 14V Shipping weight 3 0KG 6 8Lbs Packing 22x22x27cm 8x8x11 inches Model SMX 80BD Package Battery Built in Model Additional Features Built in 7AH Lead Acid Gel Battery 110 240V Travel Charger Max Charger Current DC 14V 1 A Max charging time 72 Hours including Battery Recovery Step Shipping weight 6 2KG 13 6Lbs Packing 43x45x37cm 8x8x14 inches Model SMX GP120 ...

Страница 8: ...dos etapas y el sonido de cada etapa es diferente La segunda etapa producirá ruido ruidoso ya que los cilindros duales bombean Antes de conectar la bomba de la batería asegúrese de que el voltaje de la batería es de 12V y la carga máxima de la fuente de alimentación puede soportar 30A de corriente Por favor devuelva la unidad al fabricante o al lugar de compra para servicio o reemplazo Las reparac...

Страница 9: ... de válvula debe monitorear la bomba de cerca Este tipo de válvula hace que la bomba se sobrecaliente prematuramente debido a la contrapresión causada por el diafragma de la válvula Esta contrapresión dará una falsa lectura al sensor de la bomba y hará que la segunda etapa comience temprano Esto hará que la bomba funcione más y más Nuestros adaptadores de válvula universal pueden encajar casi todo...

Страница 10: ...flado La segunda etapa nunca se iniciará ya que la función de control de presión no funciona Cuando tenga la mayor parte del aire fuera de la cámara apague la bomba y desconecte la manguera de esa cámara Debe apagar la bomba manualmente ya que no se detendrá automáticamente Advertencia Nunca deje la bomba desatendida cuando use esta función ya que puede causar daños extremos a su inflable ya la bo...

Страница 11: ...ro 8 Sensor eléctrico para la presión del aire 9 Tablero de control de la exhibición del LCD 10 Tablero de control del relais de energía 11 Otras piezas Garantía limitada de 2 años Para el uso recreativo las tarjetas eléctricas de control motor cargador están garantizados por 2 años Batería manguera de aire adaptadores de válvulas y bolsa de transporte están garantizados por 6 meses La garantía pa...

Страница 12: ...e votre pompe ou votre batterie est complètement chargée avant de l utiliser La pompe a deux étapes et le son de chaque étape est différent La 2ème étape produira un bruit bruyant puisque les deux cylindres pompent Avant de brancher la pompe de la batterie assurez vous que la tension de la batterie est de 12 V et que le chargement maximal de la source d alimentation peut supporter un courant de 30...

Страница 13: ...applications sont les mêmes que la version régulière de la pompe Valve de Boston ou Leafield Valve Certaines soupapes d air ont un diaphragme intégré pour empêcher l air de s échapper lors de la gonflement La soupape d air type Boston Leafield C7 utilise un diaphragme en caoutchouc intégré ou un diaphragme et un ressort ils provoqueront une contre pression excessive Lorsque vous gonflez des chambr...

Страница 14: ...PSI la pompe commencera la 2ème étape seulement Si la pression de réglage est inférieure à la pression de la chambre la pompe ne s allume pas Protégez le gonfleur du sable et de l eau en le gardant dans le sac de transport fourni lorsqu il n est pas utilisé Si du sable ou de l eau entre dans le gonfleur et sur la limite de maintien du filtre à air la pompe à air sera endommagée et aucune garantie ...

Страница 15: ...s périodes 1 mois ou plus endommagera la batterie Si vous avez complètement chargé la pompe juste avant de la ranger il ne devrait pas être nécessaire de la recharger pendant des mois Si vous voyez une icône de batterie faible sur l écran LCD rechargez la batterie dans les 24 heures Si la batterie ne supporte plus une charge la batterie devra peut être être remplacée dans la plupart des cas Travau...

Страница 16: ...paiera les deux frais de transport si la demande de garantie est supérieure à 180 jours à compter de la date d achat Seamax donne seulement 2 ans de garantie pour les pompes que nous avons vendues Seamax servira toutes les pompes au Canada Adresse 120 11791 Machrina Way Richmond BC Canada Tél 604 277 7766 Veuillez conserver votre reçu et les étiquettes sur la pompe pour votre service de garantie N...

Отзывы: