4.1
INSTALLATION.
4.1.1 Securely attach the press to a flat, firm, level surface taking
into account clearance for working pieces.
DANGER! The press is top heavy.
If it requires moving after
assembly or for relocation, use suitable slings around the top
crossbeam, or lift direct with a forklift with the forks located
under the top crossbeam.
DO NOT
use a pallet truck.
4.1.2 connect to an air supply as recommended in Fig.3. The air
supply must be capable of 108 to 123psi and 9cfm.
4.1.3
Purge hydraulic system.
Before operating the press, the
hydraulic system may require purging in order to eliminate
any air that may have built up during transit.
Manual Operating System:
open the release valve by turning anti-clockwise and pump the handle several times.
Air Operating System:
open the release valve by turning anti-clockwise and connect the air valve to the air line system, operate the
air valve, allowing the pump to operate until the air has been purged. Should the system malfunction at any time, repeating either of
these procedures may resolve the problem.
Fig.2
4. INSTALLATION & OPERATING
YK509FAH & YK759FAH
Issue no: 1 - 02/09/08
Fig.3