background image

2.  INTRODUCTION & SPECIFICATIONS

3.  OPERATING INSTRUCTIONS

 

WARNING! Ensure you read, understand and apply safety instructions.

3.1.

   Fit appropriate discharge pipe to pump outlet and secure with clip. Ensure the diameter of the discharge pipe is the same as, or  

 

 

greater than, the outlet diameter. A smaller pipe will adversely effect the pump flow rate. 

3.2.

 

Position pump in the water, and place the outlet pipe securely in the discharge receptacle or area. We recommend the pump is  

 

 

submerged with its discharge outlet facing up to release any trapped air.

3.3.

 

Plug the pump into the electrical mains supply and switch on.

 

The pump will automatically turn on as the level of water rises (fig.1.A). As water level lowers, the float will automatically switch the    

 

pump off as it reaches the minimum height (B). Float may be adjusted by shortening or lengthening the cable. The pump will switch on  

 

if the water level is up to or above the maximum length of the float cable. To function correctly the float must move freely. Ensure the   

 

float can do so and that the cable is not restricted. Check that the pump and discharge are working correctly.

3.4.

 

The water into which the pump is placed will act as the motor cooling agent. For this reason the pump must remain submerged at all   

 

times. Should the pump have to be used in shallow water 

DO NOT

 operate for more than 10 minutes. Failure to follow this rule will    

 

damage the unit and will invalidate your warranty.

NOTE:

 See fig.2 to determine minimum clearance required if using pump in a restricted area i.e. well, etc.

fig.1

WPD235A.V2

WPS225A.V2

fig.2

Manufactured from corrosion resistant materials with - stainless steel motor case and Noryl base cover - WPD235A.V2

   

                                                                  - stainless steel body and motor case 

- WPS225A.V2

Fitted with automatic cut-out. Designed for operation in dense and dirty water. Suitable for the effective drainage of cellars, sinks, cisterns, 

baths and the general transfer of water and dense liquids.

  Model No. 

Cut-Out  Outlet OD  Maximum 

Maximum  Motor  Input      Maximum        Minimum            Maximum

 

 

 

 

Output 

Head 

 

        Particle Size    Water Depth       Water Depth 

WPD235A.V2  Automatic 

38mm 

217ltr/min 

8mtr 

750W  230V          35mm             40mm                  7mtr

WPS225A.V2  Automatic 

38mm 

225ltr/min 

7.5mtr 

750W  230V          15mm             30mm                  5mtr