8
do not
use the pump for any purpose other than for that which it is designed.
8
do not
use to pump chemicals, fuels, salt water, sea water, inflammable, corrosive, explosive or dangerous liquids.
8
do not
use to pump septic tanks or settling pits.
8
do not
operate the pump out of water. the pump pick up area must be completely submerged during operation.
8
do not
exceed the maximum submersible depth of
7
metres.
8
do not
operate the pump during freezing temperatures.
8
do not
leave the pump in water that may freeze.
8
do not
carry the pump by its electrical cable, or outlet pipe. use the moulded handle only (fig.1).
9
When not in use, switch off the pump and remove plug from the power supply. Rinse pump, drain out any
water and store in a frost free, safe location.
warninG!
do not
allow uncontrolled discharge of contaminated water which would pollute the environment.
2.
i
introduction
manufactured from corrosion resistant materials with stainless steel motor case and noryl base cover. fitted with automatic cut-out. minimum water
depth of 40mm. designed for operation in dense and dirty water. suitable for the effective drainage of cellars, sinks, cisterns, baths and the general
transfer of water and dense liquids.
3. SpeciFication
model no:................................ ..............................
WPD133A
cutout:..................................... .............................. Automatic
outlet:...................................... ................
”x”, “y” or “z” (fig.2)
maximum output:.................... ....................
133ltr(30gal)/min
m
inimum Water Depth:............
..................................... 40mm
m
aximum Water Depth:...........
....................................... 7mtr.
maximum Particle size:........... ..................................... 30mm
maximum Head:..................... ....................................... .5mtr.
motor Power:.................................................................
400W
supply: ...........................................................................230V
4. operation
warninG!
ensure you read, understand and apply safety instructions.
important as a guide limit the maximum continuous running time for the pump to six hours, followed by three hours
downtime.
4.1.
fit an appropriate discharge pipe to pump outlet and secure with clip; inside diameter “x” “y” or “z”
(fig.2)
. ensure the diameter of the
discharge pipe is the same as, or greater than, the outlet diameter. A smaller pipe will adversely effect the pump flow rate.
4.2.
Position pump in the water, and place the outlet pipe securely in the discharge receptacle or area. We recommend the pump is
submerged with its discharge outlet facing up to release any trapped air.
4.3.
Plug the pump into the electrical mains supply and switch on. the pump will automatically turn on as the level of water rises
(fig.1a)
.
As water level lowers, the float will automatically switch the pump off as it reaches the minimum height
(fig.1b)
. the float may be
adjusted by shortening or lengthening the cable using the notch in the handle. The pump will switch on if the water level is up to or
above the maximum length of the float cable. to function correctly the float must move freely. ensure the float can do so and that the
cable is not restricted. check that the pump and discharge are working correctly.
4.4.
the water into which the pump is placed will act as the motor cooling agent. for this reason the pump must remain submerged at all
times. should the pump have to be used in shallow water (float switch overridden)
do not
operate “dry” for more than 10 minutes.
failure to follow this rule will damage the unit and will invalidate your warranty.
note:
see
fig.3
to determine minimum clearance required when using the pump in a restricted area, such as a well or a trough for
example.
5. maintenance
warninG!
With the exceptions listed below in “TROUBLESHOOTING”, all pump, float, electrical cable service maintenance and repair
must only be undertaken by an authorised service agent. failure to observe this rule may be dangerous and will invalidate your warranty.
warninG!
ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.
5.1.
Keep all parts of the pump clean. rinse, drain and allow to dry before storing pump.
5.2.
regularly check the water inlet on the base of the pump to ensure there are no blockages. to access the impeller, carefully undo the
base screws and remove base. clean impeller and replace base ensuring that the o-ring is correctly located.