Sealey WFS94X Скачать руководство пользователя страница 2

The WFS94 must be unpacked and installed indoors.
3.1.

The appliance may be used as a mobile free standing unit, or securely fixed to a level surface capable of supporting

the unit’s weight, (i.e. a cabinet).

3.2.

Allow adequate surrounding space to assure the necessary ventilation.

3.3.

To fix the extraction hose (Fig 1 A.). unclip “B” the front panel “C”, pass the hose through the centre hole and secure with large 

plastic nut “A1”.

3.

INSTALLATION

4.

OPERATING INSTRUCTIONS

5. MAINTENANCE

5.1.

General

5.1.1.

Ensure the mains switch is unplugged before attempting repair or maintenance.

5.1.2.

Keep the unit clean, wipe with a damp cloth, do not use abrasive materials.

5.1.3.

Regularly check extraction hose and head to ensure they are clean and not worn, or damaged.

5.4.

Filter Cartridge.

The durability of the filtering cartridge depends on the way the cleaner is used and the quantity 

of collected impurities. Periodically check the suction capacity of the unit and replace the 

cartridge if there should be a decrease in the unit’s performance.

5.4.1.

For easy access to the filter compartment stand the unit upright on a clean soft surface.

5.4.1.

To change the filter undo the side clasps which hold the filter cover (fig 1 B).

5.4.2.

Undo the two wing nuts (fig 2 D), remove the cover plate “E” and soiled filter “F”. Use an air line

to clean the filter compartment, fit the new filter and cover plate.

5.4.3.

Firmly re-tighten the wing nuts “D”, position the cover plate (fig C) and lock clasps “B”

(the locking clasps may be adjusted by turning the locking head).

5.4.4.

To replace the “After Filter” (at the other end of the unit), stand the unit correctly, undo hand bolts

(Fig 3 G), remove grid “H”, replace the soiled “After filter” “I” and re-fit grid “H”. 

Note:

The filter cartridges are disposable and must be placed in a sealed airtight container 

and disposed of according to local regulations relating to the type of waste contained in the filter. 

IMPORTANT: 

NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THIS EQUIPMENT.

WARRANTY: 

GUARANTEE IS 12 MONTHS FROM PURCHASE DATE. PROOF OF PURCHASE WILL BE REQUIRED FOR ANY CLAIM.

INFORMATION: 

PLEASE CALL US FOR A COPY OF OUR LATEST CATALOGUE.

Sealey Group,

Bury St. Edmunds, Suffolk.

WFS94X Job 267 060198

01284 757500

E-mail:

[email protected]

01284 703534

(Not for outside use).

4.1.

Ensure the unit is switched off and is unplugged from the mains power supply.

4.2.

Check the filter compartment end panel (Fig 1 C.). and ensure that clasps “B” are securely locked.

4.3.

Ensure the surrounding area will provide adequate ventilation, and that there are no obstructions

in front of the air outlet.

4.4.

Place the extraction head (by use of attached magnet) as close as possible to the area from 

which fumes will be emitted.

4.5.

To avoid possibility of accidents, ensure the suction hose is laid safely so that it will not obstruction pedestrian, or vehicle pathways.

4.6.

Plug into the mains power, and switch the extraction motor switch “X”, on.  (The switch will light).

4.7.

Continue to run the extraction unit for a short time after welding is completed. 

4.8.

When task is complete, switch the motor off and disconnect from the mains, clean and store the unit in a safe, dry, childproof area.     

Fig 1

Fig 2

Fig 3

Declaration of Conformity 

We, the sole importer into the UK, declare that the product listed below is in conformity with the following EEC standards and directives

The construction file for this product is held by the Manufacturer and may be inspected on

request by contacting Jack Sealey Ltd

For Jack Sealey Ltd.  Sole importer into the UK of Sealey Power Products

Signed by John Sealey

Date 1st February 1998

Welding Fume Extractor Model No: WFS94X

EEC Directive 89/392EEC Machinery

and amendments.

73/23/EEC Directive

89/336/EEC Directive & Amendments.

6.

PARTS LIST

Item       Part  No          

Item Name   

1

WFS94X/01

Filter, Cartridge

2

WFS94X/02

Motor 230v

3

WFS94X/03

Filter, Carbon activated

4

WFS94X/04

Hose, Flexible

5

WFS94X/05

Pipe, connection

6

WFS94X/06

Handle

7

WFS94X/07

Switch

8

WFS94X/08

Lamp

9

WFS94X/09

Connection, cable

Original Date:-  010298

Issue Date:-

Version Nbr:-     0

Date Modified:- N/A

Wiring diagram