4.7.5. 

  

ABNORMAL OPERATION DISPLAYS

4.7.5.1.    e-1: means the heater is not touching the fluid or the 

 

fluid does not reach to ‘To The Line’ mark.

 

IMPORTANT:

 

- When connected to the battery and heating without 

                  touching the fluid, the display will show “e-1” after 

 

  pressing the power button for 5 seconds, (air-burning

 

  prevention).

 

- The indicator light will be red, accompanied by a long

 

  “beep” sound. 

 

- Release the Power button, TemP > 320°C/608°f 

 

  (see fig.6) will disappear and show only “e-1”.

 

-  Disconnect and reconnect to the battery in order to 

 

   use the tester again.

4.7.5.2.    e-2: means either the voltage is too low (lower than 10.8V)

 

or the voltage is too high (higher than 15.7V), see fig.7.

4.7.5.3.    e-3: means either there is a problem with the heater or 

 

there is an internal fault. Contact your stockist for

 

assistance, see fig.8.

4.8. 

  

CALIBRATION TEST

4.8.1.   

To confirm the accuracy of the tester, carry out a test 

 

using clean water. 

4.8.2. 

  

If the tester is working correctly the result will be

 

Temp=100°C/212°f, see fig.9.

4.9. 

  

INSPECTION STANDARD VALUE

4.9.1.   

Please refer to the Wet Boiling Point of brake fluid on the LCD display to determine whether

 

the brake fluid needs to be replaced.

 

When testing either DOT5 or DOT5.1 brake fluid, use the DOT5 reference data on screen.

 

Both brake fluid types have virtually the same minimum boiling point, depending on brake fluid 

 manufacturer.

 

Different manufacturers of brake fluid have different compositions, so the temperature can be slightly different. The real boiling point

 

depends on the DOT type and manufacturer of brake fluid and is marked on the bottle.  

 

The Wet equilibrium Reflux Boiling Point should not be below the following temperatures:

 

DOT 3:    

140°C (284°f)

 

DOT 4:    

155°C (311°f)

 

SuPeR DOT 4:  

155°C (311°f)

 

DOT 5:    

180°C (356°f)

 

DOT 5.1:   

190°C (374°f)

Fig.6

Fig.7

Fig.8

Fig.9

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: no Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

ENVIRONMENT PROTECTION

recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 

a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 

according to local regulations.

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the eu Directive on Waste electrical and electronic equipment 
(Weee). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 

waste authority for recycling information.

Original Language Version

© Jack Sealey Limited

v

S0275 | Issue:1 - 27/10/17

Отзывы: