Sealey VEN200.V3 Скачать руководство пользователя страница 2

3.  SPECIFICATION

Model no ............................................................. VEN200.V3

Fan diameter .............................................................. 200mm

Fan speed ................................................................2800rpm

IP rating ......................................................................... IPX4

Power ............................................................................115W

Replacement parts ........................ VEN200AK1/VEN200AK2

Static pressure ..........................................................3.1mbar

Supply ............................................................................230V

4.  OPERATION

4.1.    

To extract air: attach the ducting (fig.1) to the inlet side of the 

 

ventilator, ensuring a tight fit. Secure by pulling the string tight

 

and knotting it. Locate the other end of the ducting in the area

 

from which you wish to extract air.

4.2.    

To ventilate: attach the ducting to the outside side of the ventilator

 

and locate the other end of the ducting in the area that you wish to

 ventilate.

NOTE: 

The ducting has locating lugs attached to it; these can be used to

 

suspend the ducting if required.

4.3.    

Connect the mains plug to a suitable electric supply

.

4.4.    

Move the toggle switch to start the unit; select a low or high fan

 

speed as required.

fig.1

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 

(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 
waste authority for recycling information.

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Original Language Version

© Jack Sealey Limited

Description

Symbol

Value

U

nit

M

ax. fan flow rate

F

20.55

M/min³

Fan power input

P

116.83

W

Service value

SV

0.18

(m³/min)/W

Standby power consumption

P

SB

0.00

W

Seasonal electricity consumption Q

37.39

KWh/a

Fan sound power level

LWA

81.90

D

B(A)

Max. air velocity

C

1.78

Meters/sec

Measurement standard for 

service value

IEC 

60879:1986

VEN200.V3     Issue: 1 19/01/21

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call 

our technical team on [email protected] or 01284 757505.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.