3.1.

 

To extract air, attach the ducting (fig.1) to the inlet side  

 

of the ventilator, ensuring a tight fit and secure it by 

 

pulling the string tightly and knotting it. Locate the other  

 

end of the ducting in the location you wish to extract air  

 

from. 

3.2.

 

To ventilate air, attach the ducting to the outlet side of  

 

the ventilator and locate the other end of the ducting in  

 

the area you wish to ventilate.

Note: 

The ducting has locating lugs attached to it. These can  

 

be used to suspend the ducting if required.

3.3.

 

Plug the mains plug into a suitable mains power 

 

supply.

3.4.

 

Move the toggle switch to start the unit - select a low  

 

or high fan speed as required.

2.  INTRODUCTION & SPECIFICATIONS

3.  OPERATION

Ideal for use where high volume air delivery is required. Especially suitable for ventilating confined, hot or fume laden work sites, typically as 

found in boats, cable/pipe ducts, roof spaces etc. Lightweight and robust construction give the portability and durability necessary in the work 

place. Fitted with carry handle, 2mtr cable and ASTA/BS approved plug. Supplied with 5mtr ducting.

fig.1

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

VEN200.V2, VEN250, VEN300.V2     Issue:1 - 07/02/12

Model No:  . . . . . . . . . . . . . . . . . . . VEN200.V2 . . . . . . . . . . . . VEN250  . . . . . . . . . VEN300.V2

Supply: . . . . . . . . . . . . . . . . . . . . . . . . 230V 1ph . . . . . . . . . . . 230V 1ph  . . . . . . . . . . .230V 1ph

Motor: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180W . . . . . . . . . . . . . . 240W  . . . . . . . . . . . . . .350W

Fan Diameter:. . . . . . . . . . . . . . . . . . . . .200mm . . . . . . . . . . . . . 250mm  . . . . . . . . . . . . 300mm

Fan Speed (max):. . . . . . . . . . . . . . . . .2800rpm . . . . . . . . . . . . 2800rpm  . . . . . . . . . . . 2800rpm

Air Flow: . . . . . . . . . . . . . . . . . . . . . . . 28m³/min . . . . . . . . . . . .45m³/min  . . . . . . . . . . . 63m³/min

Static Pressure:  . . . . . . . . . . . . . . . . . . 3.1mbar . . . . . . . . . . . . .3.5mbar  . . . . . . . . . . . . 3.8mbar

Weight (without ducting): . . . . . . . . . . . . . 6.7kg . . . . . . . . . . . . . . .7.9kg  . . . . . . . . . . . . . . 9.6kg

Replacement Ducting (5m): . . . . . .VEN200AK1 . . . . . . . . . VEN250AK1  . . . . . . . . VEN300AK1

Optional Ducting (10m): . . . . . . . . .VEN200AK2 . . . . . . . . . VEN250AK2  . . . . . . . . VEN300AK2

Note:

 Maximum length: . . . . . . . . . . . . . . . 10m . . . . . . . . . . . . . . . .10m  . . . . . . . . . . . . . . . 10m