background image

Original Language Version

© Jack Sealey Limited

2.  INTRODUCTION

 

Electric 12V or 230V membrane pump specifically designed for the distribution of AdBlue®. Self-priming unit provides a flow rate of up to 

 

40ltr/min. Supplied with 4mtr hose, manual delivery nozzle and battery clips (12V) or BS approved plug (230V). All materials and seals  

 

used in these pumps are suitable for use with AdBlue®.

3.  SPECIFICATION

Model no ....................................................................TP9912

Voltage .............................................................................12V

Speed.......................................................................2800rpm

Current .............................................................................18A

Power ............................................................................

260W

Duty cycle ................................................................

30min/hr

Flow rate ..................................................................

40ltr/min

W

eight ..............................................................................

6kg

4.  ASSEMBLY

4.1.    

Attach the feet of the pump unit to a stable surface using 4 suitable screws or bolts (not supplied).

4.2. 

  

Remove blanking plugs from suction (fig.1.B) and delivery (fig1.D) ports and push hoses (figs.1.A and 1.C) onto the connectors, first  

 

placing a loose hose clip over the hose

 

NOTE:

 the flow direction is marked on the pump.

4.3.    

Tighten the hose clips onto the hoses.

4.4. 

  

Immerse the suction strainer in the AdBlue

® 

container.

4.5.    

Connect to the appropriate electric power supply by means of battery clips (TP9912) or mains plug (TP99230).

5.  INSTALLATION

    

SITE INSTALLATION. It is the responsibility of the owner of the equipment to ensure that the siting of the AdBlue

®

 

container and  

 

the installation and operation of the pump is carried out in such a way as to prevent any leakage which could contaminate   

 

water courses or drinking water for people or animals. The owner should liaise with local authorities, health and safety and  

 

water authorities to ensure that the installation is safe.

6.  OPERATION

6.1. 

  

These pumps, being of positive displacement design, 

 

 

do not require priming. When first used, there will be 

 

 

a slight delay as air is cleared from the system.

6.2. 

  

To operate: switch the pump motor on using the 

 

rocker switch above the motor (O=”OFF”, I=”ON”). 

 

The motor will start.

6.3.    

Place the nozzle in the AdBlue® vessel to be filled 

 

and squeeze the delivery trigger (fig.2.A).

6.4.    

If using the latch (fig.2.B), use with care as there is no

 

 

automatic cut-off fitted to the nozzle.

6.5.    

When delivery is complete, release the delivery 

 

trigger: delivery will stop but the pump will continue 

 

to run. 

6.6. 

  

Turn the pump off using the rocker switch. 

 

To avoid damage 

DO NOT 

run the pump with no delivery for longer than necessary. 

IN NO CIRCUMSTANCES 

run in this state for  

 

more than 3 minutes.

6.7. 

  

Store the nozzle so as to prevent spillage of urea into the environment.

7.  MAINTENANCE

7.1.    

The pump has been designed for low maintenance. Should any problems occur return to your Sealey stockist.

7.2.    

Clean the entire installation and inspect all piping and connections for leaks. Rectify any damage immediately.

7.3. 

  

Inspect the filter at the end of the suction tube every time the tank is refilled. Clean if necessary.

 .................................................................................TP99230

 .......................................................................................230V

 .................................................................................2900rpm

 ...........................................................................................2A

 ......................................................................................

370W

 ..............................................................................continuous

 .................................................................................

40ltr/min

 .................................................................................... 8.47kg

fig.1

fig.2

T

P9912, TP99230 | Issue:2 (H,F) 26/10/18